Literature DB >> 33420200

Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions.

Suhaila Bohan1, Marlina Tanty Ramli Hamid2, Wai Yee Chan1, Anushya Vijayananthan1, Norlisah Ramli1, Shaleen Kaur1, Kartini Rahmat3.   

Abstract

This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of screening detected suspicious mammographic abnormalities comprising of calcifications, asymmetric densities, architectural distortions and spiculated masses. In this institutionally approved study, a total of 170 (n = 170) DBT-VABB were performed, 153 (90%) were for calcifications, 8 (4.7%) for spiculated mass, 5 (2.9%) for asymmetric density and 4 (2.4%) for architectural distortion. All these lesions were not detected on the corresponding ultrasound. Histopathology results revealed 140 (82.4%) benign, 9 (5.3%) borderline and 21 (12.4%) malignant lesions. The total upgrade rate at surgery was 40% for atypical ductal hyperplasia and 5.9% for ductal carcinoma in-situ. 3.6% discordant benign lesions showed no upgrade. DBT-VABB showed 100% specificity, 91.3% sensitivity and 100% positive predictive value (PPV) for detecting malignant lesions. The negative predictive value (NPV) was 80%. 2 (1.2%) patients had mild complications and 1 (0.6%) had severe pain. Our study showed that DBT-VABB was a safe and reliable method, with high sensitivity, specificity, PPV and NPV in the diagnosis of non-palpable benign and malignant breast lesions. Our data also confirmed the accuracy of DBT-VABB in detecting malignant lesions and we suggest further surgical excision in borderline lesions for a more accurate diagnostic evaluation.

Entities:  

Year:  2021        PMID: 33420200      PMCID: PMC7794227          DOI: 10.1038/s41598-020-80124-4

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  19 in total

1.  Digital breast Tomosynthesis vacuum assisted biopsy for Tomosynthesis-detected Sonographically occult lesions.

Authors:  Nikki S Ariaratnam; Sherrill T Little; Markus A Whitley; Kristy Ferguson
Journal:  Clin Imaging       Date:  2017-08-05       Impact factor: 1.605

2.  Diagnostic underestimation of atypical ductal hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution.

Authors:  Gustavo Machado Badan; Decio Roveda Júnior; Sebastião Piato; Eduardo de Faria Castro Fleury; Mário Sérgio Dantas Campos; Carlos Alberto Ferreira Pecci; Felipe Augusto Trocoli Ferreira; Camila D'Ávila
Journal:  Radiol Bras       Date:  2016 Jan-Feb

3.  An evaluation of patient experience during percutaneous breast biopsy.

Authors:  Jean M Seely; Fraser Hill; Susan Peddle; Jackie Lau
Journal:  Eur Radiol       Date:  2017-05-22       Impact factor: 5.315

4.  The value of stereotactic vacuum assisted breast biopsy in the investigation of microcalcifications. A six-year experience with 853 patients.

Authors:  Panagiotis M Safioleas; Dimitra Koulocheri; Nikolaos Michalopoulos; Paraskevi Liacou; Ioannis Flessas; Afroditi Nonni; Konstantinos Kontzoglou; George C Zografos
Journal:  J BUON       Date:  2017 Mar-Apr       Impact factor: 2.533

Review 5.  Early Detection and Screening for Breast Cancer.

Authors:  Cathy Coleman
Journal:  Semin Oncol Nurs       Date:  2017-03-29       Impact factor: 2.315

Review 6.  Ductal carcinoma in situ: terminology, classification, and natural history.

Authors:  D Craig Allred
Journal:  J Natl Cancer Inst Monogr       Date:  2010

7.  Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions.

Authors:  M Tonegutti; V Girardi
Journal:  Radiol Med       Date:  2008-02-25       Impact factor: 3.469

8.  Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study.

Authors:  Ute Kettritz; Kerstin Rotter; Ingrid Schreer; Margarete Murauer; Rüdiger Schulz-Wendtland; Daniela Peter; Sylvia H Heywang-Köbrunner
Journal:  Cancer       Date:  2004-01-15       Impact factor: 6.860

9.  Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

Authors:  Yew-Ching Teh; Gie-Hooi Tan; Nur Aishah Taib; Kartini Rahmat; Caroline Judy Westerhout; Farhana Fadzli; Mee-Hoong See; Suniza Jamaris; Cheng-Har Yip
Journal:  BMC Cancer       Date:  2015-05-15       Impact factor: 4.430

10.  Image-guided vacuum-assisted breast biopsy in the diagnosis of breast microcalcifications.

Authors:  Jun Liu; Linping Huang
Journal:  J Int Med Res       Date:  2018-05-17       Impact factor: 1.671

View more
  2 in total

Review 1.  Regulatory mechanisms and potential medical applications of HNF1A-AS1 in cancers.

Authors:  Yang Zhang; Jiang Shi; Junfang Luo; Cong Liu; Lixu Zhu
Journal:  Am J Transl Res       Date:  2022-06-15       Impact factor: 3.940

2.  Stereotactic breast biopsies: Radiological-pathological concordance in a South African referral unit.

Authors:  Natasha Alexander; Ilana Viljoen; Susan Lucas
Journal:  SA J Radiol       Date:  2022-08-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.