Literature DB >> 10063860

Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun.

L E Philpotts1, N A Shaheen, D Carter, R C Lange, C H Lee.   

Abstract

OBJECTIVE: The 11-gauge vacuum suction probe is an alternative to the 14-gauge needle and automatic gun for performing stereotactic core needle biopsies. This study compares rebiopsy rates after stereotactic core needle biopsies that were performed with the two methods. The study also assesses the outcomes of those repeat biopsies.
MATERIALS AND METHODS: Five hundred ninety-two stereotactic core needle biopsies using a 14-gauge needle and automatic gun and 354 using an 11-gauge vacuum suction probe were performed consecutively. Excluding malignancies, the number of cases requiring rebiopsy and the reasons for rebiopsy were determined for each group. The histologic diagnoses of the repeat biopsies were assessed.
RESULTS: The rebiopsy rate was significantly lower with the 11-gauge vacuum suction probe (9.0%) than with the 14-gauge needle and automatic gun (14.9%) (p = .013). Significant reductions were found in cases of insufficient sampling (probe, 1.7%; needle, 4.4%; p = .042) and mammographic-pathologic discrepancy (probe, 0.8%; needle, 3.4%; p = .026). The rebiopsy rate for masses was 6.1% with the vacuum probe versus 10.7% with the 14-gauge needle (p = .12) and for calcifications was 11.6% with the vacuum probe versus 23.7% with the 14-gauge needle (p = .003). After rebiopsy, the percentage of cases in which malignancy was found was 18.5% with the vacuum probe versus 13.7% with the 14-gauge needle. On rebiopsy, the percentage of malignancies found in each category were atypical hyperplasia: probe 26.7%, needle 20.0%; insufficient sample: probe 0%, needle 9.5%; pathologist recommendation: probe 50.0%, needle 12.5%; and lobular carcinoma in situ: probe 0%, needle 100%.
CONCLUSION: Use of the 11-gauge vacuum-assisted device significantly decreases but does not eliminate the need for rebiopsy after stereotactic core needle biopsy. The rebiopsy rate for calcifications was significantly reduced by using the vacuum suction probe rather than the 14-gauge needle; however, the rate for masses was reduced only slightly. On rebiopsy, malignancies were found in both groups.

Entities:  

Mesh:

Year:  1999        PMID: 10063860     DOI: 10.2214/ajr.172.3.10063860

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

Review 1.  Early breast cancer.

Authors:  Tomoyoshi Suzuki; Masakazu Toi; Shigehira Saji; Kazumi Horiguchi; Tomoyuki Aruga; Eiji Suzuki; Shinichiro Horiguchi; Nobuaki Funata; Katsuyuki Karasawa; Noriko Kamata
Journal:  Int J Clin Oncol       Date:  2006-04       Impact factor: 3.402

Review 2.  Stereotactic and ultrasound-guided breast biopsy.

Authors:  T H Helbich; W Matzek; M H Fuchsjäger
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

3.  Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings.

Authors:  Min Jung Kim; Eun-Kyung Kim; Ji Young Lee; Ji Hyun Youk; Byeong-Woo Park; Seung-Il Kim; Haeryoung Kim; Ki Keun Oh
Journal:  Eur Radiol       Date:  2007-03-15       Impact factor: 5.315

Review 4.  An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens.

Authors:  E A Rakha; I O Ellis
Journal:  J Clin Pathol       Date:  2007-07-14       Impact factor: 3.411

5.  Minimally Invasive Biopsy Methods - Diagnostics or Therapy? Personal Opinion and Review of the Literature.

Authors:  Ute Kettritz
Journal:  Breast Care (Basel)       Date:  2011-04-29       Impact factor: 2.860

6.  Efficacy and cost-effectiveness of stereotactic vacuum-assisted core biopsy of nonpalpable breast lesions: analysis of 602 biopsies performed over 5 years.

Authors:  A Luparia; M Durando; P Campanino; E Regini; D Lucarelli; A Talenti; G Mattone; G Mariscotti; A Sapino; G Gandini
Journal:  Radiol Med       Date:  2011-01-12       Impact factor: 3.469

7.  Values of pathological analysis of lost tissue fragments in the vacuum canister during a vacuum-assisted stereotactic biopsy of the breast.

Authors:  M El Khoury; B Mesurolle; A Omeroglu; A Aldis; E Kao
Journal:  Br J Radiol       Date:  2013-03-21       Impact factor: 3.039

8.  A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

Authors:  Xu Chen Huang; Xu Hua Hu; Xiao Ran Wang; Chao Xi Zhou; Fei Fei Wang; Shan Yang; Gui Ying Wang
Journal:  Ir J Med Sci       Date:  2018-03-16       Impact factor: 1.568

9.  Randomized controlled trial of stereotactic 11-G vacuum-assisted core biopsy for the diagnosis and management of mammographic microcalcification.

Authors:  Sara M Bundred; Anthony J Maxwell; Julie Morris; Yit Y Lim; Md Janick Harake; Sigrid Whiteside; Nigel J Bundred
Journal:  Br J Radiol       Date:  2015-12-14       Impact factor: 3.039

Review 10.  Modern concepts of ductal carcinoma in situ (DCIS) and its diagnosis through percutaneous biopsy.

Authors:  Ute Kettritz
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.