One hundred seventy-five patients with 243 consecutive primary Press Fit Condylar cruciate-substituting total knee replacements were evaluated at a mean of 5.5 years. One hundred thirteen knees had modular metal-backed tibial components and 130 had all-polyethylene tibial components. The mean knee score and functional score for the patients with unrevised components was not significantly different. The incidence of osteolysis and synovitis was higher in patients in the modular metal-backed tibia group (5%; five patients, six knees). No patients in the all-polyethylene tibia group had osteolysis or synovitis. Five revision operations were necessary: four for osteolytic defects and one for synovitis, all in patients in the modular metal-backed tibia group. All of the retrieved polyethylene inserts had evident backside wear. The best case rate of survival of the all-polyethylene tibial components was 96%+/-0.8% at 7 years and for the modular metal-backed components it was 75%+/-10% at 7 years. Metal backing and modularity were added to the Press Fit Condylar total knee replacement design to improve fixation durability. However, the superiority of the modular metal-backed implants remains in question.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11716380     DOI: 10.1097/00003086-200111000-00021

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  17 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Pulsed lavage improves fixation strength of cemented tibial components.

Authors:  Ulf J Schlegel; Jan Siewe; Karl S Delank; Peer Eysel; Klaus Püschel; Michael M Morlock; Anne Gebert de Uhlenbrock
Journal:  Int Orthop       Date:  2010-10-16       Impact factor: 3.075

3.  Do "premium" joint implants add value?: analysis of high cost joint implants in a community registry.

Authors:  Terence J Gioe; Amit Sharma; Penny Tatman; Susan Mehle
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

5.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

6.  [Current role of minimally invasive total knee arthroplasty. A meta-analysis].

Authors:  T Kappe; M Flören; R Bieger; H Reichel
Journal:  Orthopade       Date:  2011-08       Impact factor: 1.087

7.  All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties.

Authors:  Mustafa Yassin; Avraham Garti; Moshe Weissbrot; Uzi Ashkenazi; Muhammed Khatib; Dror Robinson
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-05-26

8.  All-polyethylene tibial components in obese patients are associated with low failure at midterm followup.

Authors:  David F Dalury; Kimberly K Tucker; Todd C Kelley
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 9.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

10.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.