Literature DB >> 18321877

Radiation detector developments in medical applications: inorganic scintillators in positron emission tomography.

Carel W E van Eijk1.   

Abstract

In recent years, a number of new gamma-ray scintillators are commercially available. These scintillators are either derived from known scintillators, e.g. Lu1-xYxAlO3: Ce (LuYAP) from LuAlO3:Ce and Lu(2(1-x))Y2xSiO5:Ce (LYSO) from Lu2SiO5:Ce or are the result of new discoveries, e.g. LaCl3:Ce and LaBr3:Ce. The first two materials are primarily of interest because of the relatively high detection efficiency and fast response; LYSO has found application in time-of-flight (TOF) positron-emission tomography (TOF PET) and the LuYAP-LYSO combination is used in small-animal PET. The halide scintillators have an excellent energy resolution of approximately 3% at 662 keV and they have a relatively high light yield. LaBr3:Ce is being studied for application in TOF PET. At the same time, the search for and research on new scintillator materials are going on. For example, LuI3:Ce is a new material with a very high light yield (approximately 90,000 photons MeV(-1)). Other examples of new materials are (C6H13NH3)2PbI4 and (C3H7NH3)2PbBr4, organic-inorganic hybrid compounds, of which the former has a very fast sub-nanosecond response. The new scintillators show great promise for new developments in medical applications, in particular, for PET systems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18321877     DOI: 10.1093/rpd/ncn043

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

1.  Hybrid x-ray/optical luminescence imaging: characterization of experimental conditions.

Authors:  C M Carpenter; C Sun; G Pratx; R Rao; L Xing
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  A Design of a PET Detector Using Micro-Channel Plate Photomultipliers with Transmission-Line Readout.

Authors:  H Kim; H Frisch; C-T Chen; J-F Genat; F Tang; W W Moses; W S Choong; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010       Impact factor: 1.455

3.  Optimization of time-of-flight reconstruction on Philips GEMINI TF.

Authors:  Stefaan Vandenberghe; Larry van Elmbt; Michel Guerchaft; Enrico Clementel; Jeroen Verhaeghe; Anne Bol; Ignace Lemahieu; Max Lonneux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

Review 4.  Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Authors:  Juan José Vaquero; Paul Kinahan
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

5.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

6.  Underestimated Color Centers: Defects as Useful Reducing Agents in Lanthanide-Activated Luminescent Materials.

Authors:  Markus Suta; Flavie Lavoie-Cardinal; Claudia Wickleder
Journal:  Angew Chem Int Ed Engl       Date:  2020-04-23       Impact factor: 15.336

  6 in total