Late results of absorbable pin fixation in the treatment of radial head fractures.

Panagiotis K Givissis1, Panagiotis D Symeonidis, Konstantinos T Ditsios, Panagiotis S Dionellis, Anastasios G Christodoulou.   

Abstract

The use of bioabsorbable pins with prolonged degradation periods for fracture fixation has raised concerns about adverse soft tissue reactions, including seromas, discharging sinuses, or osteolytic changes. We asked whether bioabsorbable pins of self-reinforced polylactic acid polymer used in radial head fractures resulted in such reactions. We retrospectively reviewed 21 patients followed a minimum of 36 months (mean, 81 months; range, 36-136 months). There were nine Mason II, 10 Mason III, and two Mason IV fractures, which were evaluated clinically and radiographically. All fractures healed well with no radiographic signs of osteolysis. The mean Mayo Elbow Performance score was 93.8 (range, 20-100), which is comparable to the outcome of historical groups with radial head arthroplasty. The mean range of flexion of the elbow was 9 degrees to 132 degrees , with 79 degrees pronation and 77 degrees supination. The grip strength of the operated arm was not affected in comparison to the contralateral arm (mean range, 38.6 versus 40.9 kg). No material-related adverse effects were observed during and beyond the degradation period. Our data suggest concerns about soft tissue or bony reactions from these materials in radial head fractures are not justified.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18317861      PMCID: PMC2311474          DOI: 10.1007/s11999-008-0134-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

1.  Some observations on fractures of the head of the radius with a review of one hundred cases.

Authors:  M L MASON
Journal:  Br J Surg       Date:  1954-09       Impact factor: 6.939

2.  Absorbable polyglycolide pins in fixation of displaced fractures of the radial head.

Authors:  E Hirvensalo; O Böstman; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

3.  Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study.

Authors:  Hanns-Joachim Helling; Axel Prokop; Hans Ulrich Schmid; Michael Nagel; Jürgen Lilienthal; Klaus Emil Rehm
Journal:  J Shoulder Elbow Surg       Date:  2006 Jul-Aug       Impact factor: 3.019

4.  A 5-year in vitro and in vivo study of the biodegradation of polylactide plates.

Authors:  R Suuronen; T Pohjonen; J Hietanen; C Lindqvist
Journal:  J Oral Maxillofac Surg       Date:  1998-05       Impact factor: 1.895

5.  A comparative radiological assessment of polylactide pins over 3 years in vivo.

Authors:  Axel Prokop; Axel Jubel; Ulrich Hahn; Martin Dietershagen; Mirko Bleidistel; Christiane Peters; Andreas Höfl; Klaus E Rehm
Journal:  Biomaterials       Date:  2005-07       Impact factor: 12.479

Review 6.  Adverse tissue reactions to bioabsorbable fixation devices.

Authors:  O M Böstman; H K Pihlajamäki
Journal:  Clin Orthop Relat Res       Date:  2000-02       Impact factor: 4.176

Review 7.  Comminuted fractures of the radial head: comparison of resection and internal fixation. Surgical technique.

Authors:  Masayoshi Ikeda; Kazuhiro Sugiyama; Chonte Kang; Tomonori Takagaki; Yoshinori Oka
Journal:  J Bone Joint Surg Am       Date:  2006-03       Impact factor: 5.284

8.  Fractures of the radial head treated by internal fixation: late results in 26 cases.

Authors:  R D Esser; S Davis; T Taavao
Journal:  J Orthop Trauma       Date:  1995       Impact factor: 2.512

Review 9.  Use of bioabsorbable osteofixation devices in the hand.

Authors:  E Waris; N Ashammakhi; O Kaarela; T Raatikainen; J Vasenius
Journal:  J Hand Surg Br       Date:  2004-12

Review 10.  Fractures of the radial head and neck: current concepts in management.

Authors:  Nirmal C Tejwani; Hemang Mehta
Journal:  J Am Acad Orthop Surg       Date:  2007-07       Impact factor: 3.020

View more
  6 in total

1.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

2.  Successful fixation of Mason type 2 radial head fractures using Meniscus Arrows.

Authors:  Dirk A Ottink; Stefan W A M van Zutphen; Ron van Doorn; Diederick B Wouters
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-13       Impact factor: 4.342

3.  [Effectiveness of internal fixation with headless compression hollow embedding screws for intraarticular fracture of elbow].

Authors:  Liang Duan; Liqun Gong; Yayi Fan; Jie Qi; Weiwei Li; Wenbo Wei; Wei Zhao
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-08-15

4.  Bioabsorbable vs. titanium screws for first tarsometatarsal joint arthrodesis: An in-vitro study.

Authors:  Nikke Partio; Ville M Mattila; Heikki Mäenpää
Journal:  J Clin Orthop Trauma       Date:  2019-08-28

5.  Lateral condyle fracture of the humerus in children treated with bioabsorbable materials.

Authors:  Véronique Andrey; Stéphane Tercier; Frédéric Vauclair; Aline Bregou-Bourgeois; Nicolas Lutz; Pierre-Yves Zambelli
Journal:  ScientificWorldJournal       Date:  2013-10-09

6.  Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III.

Authors:  Luigi Tarallo; Raffaele Mugnai; Martina Rocchi; Francesco Capra; Fabio Catani
Journal:  BMC Musculoskelet Disord       Date:  2018-03-27       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.