Literature DB >> 32405207

Bioabsorbable vs. titanium screws for first tarsometatarsal joint arthrodesis: An in-vitro study.

Nikke Partio1, Ville M Mattila2, Heikki Mäenpää1.   

Abstract

BACKGROUND: The TMT-1 joint arthrodesis is a common repair for severe hallux valgus. Two crossing interfragmental screws, usually titanium or steel, and a locking plate or a plate with a compression screw are the most common fixation methods for first TMT joint arthrodesis. The qualities of an ideal fixation material include adequate strength and rigidity, biocompatibility, lack of interference with bone healing, lack of visibility and palpability, and a low risk of surgical removal. We sought to determine whether bioabsorbable cannulated screws would perform as well as titanium screws in anatomical models.
METHODS: Identical anatomical TMT-1 arthrodesis was created with a saw by making a straight cut in 30 anatomical models (Sawbone®). The bioabsorbable and titanium screws were placed one at a time in exactly the same location in each model according to careful measurements. All 30 models were analyzed with a material testing machine (MTS Insight 30, Eden Prairie, USA). Each model was oriented 15° to the platform to simulate its position to the ground during mid-stance.
RESULTS: In the single-cycle load-to-failure test, the mean yield load was 61.4 N ± 5.7 N (range, 50.1 N-70.3 N) in the bioabsorbable screw group and 81.2 N ± 12 N (range, 61.7 N-113.4 N) in the titanium screw group (P < .001). The respective values for the stiffness of the fixation were 8.1 N/mm ± 0.8 N/mm (range, 6.7 N/mm to 9.1 N/mm) and 9.7 N/mm ± 1.8 N/mm (range, 6.9 N/mm to 12.6 N/mm) for the bioabsorbable and titanium groups (P = .004). The mean maximum failure loads in the bioabsorbable group were 85.1 N ± 8.5 N (range, 67.1 N-97.2 N) and in the titanium group 120.6 N ± 13.2 N (range, 96.7 N-136.7 N), respectively (P < .001). Analysis of the failure models shows bioabsorbable fixation failures caused by bending occur more often than in the titanium group.
CONCLUSION: In biomechanical testing, titanium screws were stronger than bioabsorbable screws in the TMT-1 arthrodesis model tested, although bioabsorbable cannulated screws may be an alternative to titanium screws in the fixation Lapidus procedure.
© 2019 Delhi Orthopedic Association. All rights reserved.

Entities:  

Keywords:  Bioabsorbable; Biomechanical testing; Hallux Valgus; TMT-1 arthrodesis

Year:  2019        PMID: 32405207      PMCID: PMC7211808          DOI: 10.1016/j.jcot.2019.08.017

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  35 in total

Review 1.  Modern concepts in the treatment of hallux valgus.

Authors:  A H N Robinson; J P Limbers
Journal:  J Bone Joint Surg Br       Date:  2005-08

2.  Surgical strategies: the Lapidus procedure.

Authors:  Brian C Toolan
Journal:  Foot Ankle Int       Date:  2007-10       Impact factor: 2.827

Review 3.  Rate of nonunion after first metatarsal-cuneiform arthrodesis using joint curettage and two crossed compression screw fixation: a systematic review.

Authors:  Michael P Donnenwerth; Sara L Borkosky; Bradley P Abicht; Elizabeth J Plovanich; Thomas S Roukis
Journal:  J Foot Ankle Surg       Date:  2011-09-10       Impact factor: 1.286

4.  First Tarsometatarsal Joint Derotational Arthrodesis for Flexible Hallux Valgus: Results from Follow-Up of 3-8 Years.

Authors:  T Klemola; O Savola; P Ohtonen; R Ojala; J Leppilahti
Journal:  Scand J Surg       Date:  2017-03-01       Impact factor: 2.360

5.  Correction power and complications of first tarsometatarsal joint arthrodesis for hallux valgus deformity.

Authors:  Madeleine Willegger; Johannes Holinka; Robin Ristl; Axel Hugo Wanivenhaus; Reinhard Windhager; Reinhard Schuh
Journal:  Int Orthop       Date:  2014-11-28       Impact factor: 3.075

6.  Bioabsorbable fixation in the treatment of proximal tibial osteotomies and fractures. A clinical study.

Authors:  P Tuompo; E Partio; P Rokkanen
Journal:  Ann Chir Gynaecol       Date:  1999

7.  Bioabsorbable screw fixation for the treatment of ankle fractures.

Authors:  Antti Joukainen; Esa K Partio; Pekka Waris; Jaakko Joukainen; Heikki Kröger; Pertti Törmälä; Pentti Rokkanen
Journal:  J Orthop Sci       Date:  2007-01-31       Impact factor: 1.601

8.  First tarsometatarsal joint derotational arthrodesis--a new operative technique for flexible hallux valgus without touching the first metatarsophalangeal joint.

Authors:  Tero Klemola; Juhana Leppilahti; Salla Kalinainen; Pasi Ohtonen; Risto Ojala; Olli Savola
Journal:  J Foot Ankle Surg       Date:  2013-11-13       Impact factor: 1.286

9.  Self-reinforced absorbable screws in the fixation of displaced ankle fractures: a prospective clinical study of 152 patients.

Authors:  E K Partio; O Böstman; E Hirvensalo; S Vainionpää; K Vihtonen; H Pätiälä; P Törmälä; P Rokkanen
Journal:  J Orthop Trauma       Date:  1992       Impact factor: 2.512

10.  Bioabsorbable Versus Metal Screw in the Fixation of Tibial Tubercle Transfer: A Cadaveric Biomechanical Study.

Authors:  Janne T Nurmi; Ari Itälä; Raine Sihvonen; Petri Sillanpää; Pekka Kannus; Harri Sievänen; Teppo L N Järvinen
Journal:  Orthop J Sports Med       Date:  2017-07-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.