Literature DB >> 18310749

The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up.

Y-H Kim1.   

Abstract

This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.

Entities:  

Mesh:

Year:  2008        PMID: 18310749     DOI: 10.1302/0301-620X.90B3.20096

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  14 in total

1.  Long-term results and bone remodeling after THA with a short, metaphyseal-fitting anatomic cementless stem.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim; Jun-Seok Kang
Journal:  Clin Orthop Relat Res       Date:  2013-10-26       Impact factor: 4.176

2.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

3.  Total hip arthroplasty in patients with Down's syndrome.

Authors:  Yona Kosashvili; Drew Taylor; David Backstein; Oleg Safir; Boaz Liberman; Dror Lakstein; Allan Gross
Journal:  Int Orthop       Date:  2010-05-05       Impact factor: 3.075

4.  A concise minimum eight year follow-up of proximally porous-coated tapered titanium femoral stem in primary total hip arthroplasty.

Authors:  Benjamin Beecher; Philip Glassner; Henrik Malchau; Young-Min Kwon
Journal:  Int Orthop       Date:  2012-03-14       Impact factor: 3.075

5.  Total hip arthroplasty in developmental dysplasia of the hip: Review of anatomy, techniques and outcomes.

Authors:  Scott Yang; Quanjun Cui
Journal:  World J Orthop       Date:  2012-05-18

6.  Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years.

Authors:  Pål Benum; Arild Aamodt
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

7.  A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty.

Authors:  Young-Hoo Kim; Jang-Won Park; Sourabh S Kulkarni; Yoon-Hong Kim
Journal:  Int Orthop       Date:  2013-08-03       Impact factor: 3.075

Review 8.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

9.  Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs.

Authors:  Gholam Hossein Shahgheraghi; Frcs C Seyed Ali Hashemi
Journal:  Iran J Med Sci       Date:  2015-09

10.  Morphological study of the newly designed cementless femoral stem.

Authors:  Mohd Yusof Baharuddin; Sh-Hussain Salleh; Ahmad Hafiz Zulkifly; Muhammad Hisyam Lee; Alias Mohd Noor
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.