Literature DB >> 22410972

A concise minimum eight year follow-up of proximally porous-coated tapered titanium femoral stem in primary total hip arthroplasty.

Benjamin Beecher1, Philip Glassner, Henrik Malchau, Young-Min Kwon.   

Abstract

PURPOSE: Our goal was to assess clinical and radiographic outcomes using a second-generation circumferentially proximally porous-coated titanium alloy stem at a minimum of eight years of follow-up.
METHODS: Ninety-one hips (80 patients) with Fibre Metal Taper (FMT, Zimmer Inc, Warsaw, IN, USA) femoral stems implanted between May 1998 and April 2002 were followed prospectively and re-evaluated at a minimum of eight years postoperatively. The median patient age was 56 (range 34-78) years, with 40 women and 40 men. Radiographic data and clinical follow-up using Harris Hip Score (HHS) and EuroQol (EQ)-5D outcome measures were evaluated.
RESULTS: Mean follow-up was 9.61 (range 8-12.3) years. At the time of the most recent follow-up, the mean HHS was 85.8 (range 46-100) points, mean EQ-5D Weighted Health State Index was 0.76 (range 0.05-1.00), and mean EQ-5D Visual Analogue Score was 80 (range 24-100). All stems were biologically stable, with all hips having osseous ingrowth. One stem was revised due to early periprosthetic fracture with stem subsidence. No hip had diaphyseal osteolysis.
CONCLUSIONS: To our knowledge, the data presented here represent the longest clinical follow-up of this second-generation cementless, proximally porous-coated femoral stem. The stems were found to perform well clinically and radiographically beyond the first five years previously reported in the literature. Patients had high levels of satisfaction and function, and osseous fixation occurred reliably without evidence of distal osteolysis.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22410972      PMCID: PMC3535046          DOI: 10.1007/s00264-012-1515-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  The first 32 years of total hip arthroplasty. One surgeon's perspective.

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

2.  A second-generation cementless total hip arthroplasty mean 9-year results.

Authors:  Jonathan W Surdam; Michael J Archibeck; Steven C Schultz; Daniel W Junick; Richard E White
Journal:  J Arthroplasty       Date:  2007-02       Impact factor: 4.757

Review 3.  Cemented versus cementless total hip arthroplasty. A critical review.

Authors:  R H Rothman; J C Cohn
Journal:  Clin Orthop Relat Res       Date:  1990-05       Impact factor: 4.176

4.  Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates.

Authors:  R G Geesink; K de Groot; C P Klein
Journal:  Clin Orthop Relat Res       Date:  1987-12       Impact factor: 4.176

5.  The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years.

Authors:  J C Clohisy; W H Harris
Journal:  J Arthroplasty       Date:  1999-12       Impact factor: 4.757

6.  Twenty-year results of the cementless Corail stem.

Authors:  Jean-Pierre Vidalain
Journal:  Int Orthop       Date:  2010-09-03       Impact factor: 3.075

7.  Prospective evaluation of total hip arthroplasty with a cementless, anatomically designed, porous-coated femoral implant: mean 11-year follow-up.

Authors:  J B V Butler; David Lansky; Paul J Duwelius
Journal:  J Arthroplasty       Date:  2005-09       Impact factor: 4.757

8.  21-year results of the uncemented fully textured lord hip prosthesis.

Authors:  Javier S Martínez de Aragón; Kjell S Keisu
Journal:  Clin Orthop Relat Res       Date:  2007-01       Impact factor: 4.176

9.  A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability.

Authors:  B D Mulliken; R B Bourne; C H Rorabeck; N Nayak
Journal:  J Bone Joint Surg Am       Date:  1996-08       Impact factor: 5.284

10.  The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model.

Authors:  J E Feighan; V M Goldberg; D Davy; J A Parr; S Stevenson
Journal:  J Bone Joint Surg Am       Date:  1995-09       Impact factor: 5.284

View more
  1 in total

1.  Effects of porous tantalum on periprosthetic bone remodeling around metaphyseal filling femoral stem: a multicenter, prospective, randomized controlled study.

Authors:  Goro Motomura; Naohiko Mashima; Hiroshi Imai; Akihiro Sudo; Masahiro Hasegawa; Harumoto Yamada; Mitsuhiro Morita; Naoto Mitsugi; Ryosuke Nakanishi; Yasuharu Nakashima
Journal:  Sci Rep       Date:  2022-01-18       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.