Literature DB >> 18270713

CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track.

Christian Billich1, Rainer Muche, Gerhard Brenner, Stefan A Schmidt, Stefan Krüger, Hans-Jürgen Brambs, Sandra Pauls.   

Abstract

This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18270713     DOI: 10.1007/s00330-008-0872-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

1.  Precise biopsy localization by computer tomography.

Authors:  J R Haaga; R J Alfidi
Journal:  Radiology       Date:  1976-03       Impact factor: 11.105

2.  Outpatient treatment of iatrogenic pneumothorax after needle biopsy.

Authors:  K T Brown; L A Brody; G I Getrajdman; T E Napp
Journal:  Radiology       Date:  1997-10       Impact factor: 11.105

Review 3.  Technical aspects of needle aspiration lung biopsy: a personal perspective.

Authors:  E H Moore
Journal:  Radiology       Date:  1998-08       Impact factor: 11.105

4.  Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?

Authors:  J P Ko; J O Shepard; E A Drucker; S L Aquino; A Sharma; B Sabloff; E Halpern; T C McLoud
Journal:  Radiology       Date:  2001-02       Impact factor: 11.105

5.  Transthoracic needle aspiration biopsy: evaluation of the blood patch technique.

Authors:  E L Surprenant
Journal:  Radiology       Date:  1988-07       Impact factor: 11.105

6.  Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: a pilot study.

Authors:  A Skupin; F Gomez; M Husain; C Skupin; O Bigman
Journal:  Ann Thorac Surg       Date:  1987-04       Impact factor: 4.330

7.  Needle aspiration lung biopsy: reevaluation of the blood patch technique in an equine model.

Authors:  E H Moore; D K Shelton; E R Wisner; M L Richardson; D M Bishop; J M Brock
Journal:  Radiology       Date:  1995-07       Impact factor: 11.105

8.  Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided Biopsy--comparison of diagnostic yields and complications.

Authors:  Sanjay Gupta; Savitri Krishnamurthy; Lyle D Broemeling; Frank A Morello; Michael J Wallace; Kamran Ahrar; David C Madoff; Ravi Murthy; Marshall E Hicks
Journal:  Radiology       Date:  2005-02       Impact factor: 11.105

9.  Fibrin glue for sealing the needle track in fine-needle percutaneous lung biopsy using a coaxial system: Part II--Clinical study.

Authors:  T Petsas; D Siamblis; C Giannakenas; K Tepetes; D Dougenis; K Spiropoulos; I Fezoulis; I Dimopoulos
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Nov-Dec       Impact factor: 2.740

10.  Usefulness of the blood patch technique after transthoracic needle aspiration biopsy.

Authors:  S J Herman; G L Weisbrod
Journal:  Radiology       Date:  1990-08       Impact factor: 11.105

View more
  19 in total

1.  Safer lung biopsy techniques: fewer patients with pneumothorax, fewer chest tube insertions.

Authors:  Kamran Ahrar
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

2.  Rapid needle-out patient-rollover approach after CT-guided lung biopsy: challenges and future directions.

Authors:  Ailbhe C O'Neill; Neasa Ní Mhuircheartaigh; Jonathan D Dodd
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

Review 3.  Common complications of nonvascular percutaneous thoracic interventions: diagnosis and management.

Authors:  Azzam Khankan; Shireen Sirhan; Fadi Aris
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

4.  CT-guided transthoracic biopsy: histopathologic results and complication rates.

Authors:  Aykut Recep Aktaş; Emel Gözlek; Ömer Yılmaz; Mustafa Kayan; Nisa Ünlü; Hakan Demirtaş; Bumin Değirmenci; Mustafa Kara
Journal:  Diagn Interv Radiol       Date:  2015 Jan-Feb       Impact factor: 2.630

5.  Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients.

Authors:  Jung Im Kim; Chang Min Park; Sang Min Lee; Jin Mo Goo
Journal:  Eur Radiol       Date:  2015-02-01       Impact factor: 5.315

6.  Efficacy of Tract Embolization After Percutaneous Pulmonary Radiofrequency Ablation.

Authors:  Michael Dassa; Jean Izaaryene; Nassima Daidj; Gilles Piana
Journal:  Cardiovasc Intervent Radiol       Date:  2021-01-25       Impact factor: 2.740

7.  Risks of Transthoracic Needle Biopsy: How High?

Authors:  Renda Soylemez Wiener; Daniel C Wiener; Michael K Gould
Journal:  Clin Pulm Med       Date:  2013-01-01

8.  Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

Authors:  Judy U Ahrar; Sanjay Gupta; Joe E Ensor; Armeen Mahvash; Sharjeel H Sabir; Joseph R Steele; Stephen E McRae; Rony Avritscher; Steven Y Huang; Bruno C Odisio; Ravi Murthy; Kamran Ahrar; Michael J Wallace; Alda L Tam
Journal:  Cardiovasc Intervent Radiol       Date:  2016-11-08       Impact factor: 2.740

9.  Manual aspiration in the biopsy-side down position to deal with delayed pneumothorax after lung biopsy.

Authors:  Li-Chuan Zeng; Han-Feng Yang; Xiao-Xue Xu; Ming-Guo Xie; Hua-Qiang Liao; Yu-Dong Zhang; Qu Wang; Yong Du
Journal:  J Thorac Dis       Date:  2018-01       Impact factor: 2.895

10.  Precision of coaxial needle placement in computed tomography-guided transthoracic needle biopsy.

Authors:  Rui Huang; Nan-Chuan Jiang; Hao-Hao Lu; Yu-Hui Wang; Hui Li; He-Shui Shi; Ping Han
Journal:  Exp Ther Med       Date:  2013-09-02       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.