Literature DB >> 15673500

Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided Biopsy--comparison of diagnostic yields and complications.

Sanjay Gupta1, Savitri Krishnamurthy, Lyle D Broemeling, Frank A Morello, Michael J Wallace, Kamran Ahrar, David C Madoff, Ravi Murthy, Marshall E Hicks.   

Abstract

PURPOSE: To retrospectively compare the diagnostic yield and complications associated with the use of short versus long needle paths for computed tomography (CT)-guided biopsy of small subpleural lung lesions.
MATERIALS AND METHODS: The study was approved by the institutional review board, and the requirement for informed patient consent was waived. The medical and imaging records of patients who underwent CT-guided biopsy of subpleural pulmonary nodules measuring up to 2 cm in diameter were reviewed. The study included 176 patients (79 men, 97 women; age range, 18-84 years) who were divided into two groups: In group A, a direct approach in which the needle traversed a short lung segment was used. In group B, an indirect approach involving the use of a longer needle path was used. Diagnostic yield, accuracy, and pneumothorax and chest tube placement rates were compared between the two groups. Two-tailed t tests and Pearson chi(2) tests were used to analyze continuous and categorized variables, respectively.
RESULTS: Group A comprised 48 patients; and group B, 128 patients. The mean needle path length was 0.4 cm in group A and 5.6 cm in group B. The short-path approach necessitated more needle punctures (mean, 2.9 vs 1.8 with long-path approach, P < .001) through the pleura. The diagnostic yield in group A was significantly lower than that in group B (71% vs 94%, P < .001), particularly in patients with small (0-1-cm) nodules (40% in group A vs 94% in group B, P < .001). The frequency of postbiopsy pneumothorax was identical (69%) in the two groups. However, more group B than group A patients required chest tube placement for treatment of pneumothorax (38% vs 17%, P = .006).
CONCLUSION: Use of long-needle-path biopsy of subpleural lesions resulted in a higher diagnostic yield, especially for small nodules. However, compared with the short-needle-path technique, this approach was associated with a higher frequency of chest tube placement for pneumothorax. (c) RSNA, 2005.

Entities:  

Mesh:

Year:  2005        PMID: 15673500     DOI: 10.1148/radiol.2342031423

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

1.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

2.  Electromagnetic navigation diagnostic bronchoscopy: a prospective study.

Authors:  Thomas R Gildea; Peter J Mazzone; Demet Karnak; Moulay Meziane; Atul C Mehta
Journal:  Am J Respir Crit Care Med       Date:  2006-07-27       Impact factor: 21.405

3.  Meta-analysis of the diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules.

Authors:  Weisan Zhang; Shuo Chen; Xifeng Dong; Ping Lei
Journal:  J Thorac Dis       Date:  2015-05       Impact factor: 2.895

4.  Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance.

Authors:  Geoff Nelson; Meng Wu; Cameron Hinkel; Ganesh Krishna; Tobias Funk; Jarrett Rosenberg; Rebecca Fahrig
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

5.  C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules.

Authors:  Chiara Floridi; Alessandra Muollo; Federico Fontana; Nicola Rotolo; Anna Maria Ierardi; Ejona Duka; Carlo Pellegrino; Gianpaolo Carrafiello
Journal:  Radiol Med       Date:  2014-05-28       Impact factor: 3.469

6.  Utility of contrast-enhanced ultrasound with SonoVue in biopsy of small subpleural nodules.

Authors:  Jinlin Wang; Dazhi Zhou; Xiaohong Xie; Panxiao Shen; Yunxiang Zeng
Journal:  Int J Clin Exp Med       Date:  2015-09-15

7.  Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

Authors:  Geoff Nelson; Sungwon Yoon; Ganesh Krishna; Brian Wilfley; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

8.  Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies.

Authors:  M De Filippo; M Onniboni; M Rusca; P Carbognani; L Ferrari; A Guazzi; A Casalini; E Verardo; V Cataldi; M Tiseo; N Sverzellati; G Chiari; E Rabaiotti; A Corsi; G Cacciani; M Sommario; A Ardizzoni; M Zompatori
Journal:  Radiol Med       Date:  2008-09-25       Impact factor: 3.469

9.  CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track.

Authors:  Christian Billich; Rainer Muche; Gerhard Brenner; Stefan A Schmidt; Stefan Krüger; Hans-Jürgen Brambs; Sandra Pauls
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

10.  Risk factors for hemoptysis complicating 17-18 gauge CT-guided transthoracic needle core biopsy: multivariate analysis of 249 procedures.

Authors:  Guillaume Chassagnon; Jules Gregory; Marc Al Ahmar; Pierre Magdeleinat; Paul Legmann; Joel Coste; Marie Pierre Revel
Journal:  Diagn Interv Radiol       Date:  2017 Sep-Oct       Impact factor: 2.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.