Literature DB >> 3551860

Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: a pilot study.

A Skupin, F Gomez, M Husain, C Skupin, O Bigman.   

Abstract

To explore the possibility of performing percutaneous lung biopsy safely in patients mechanically ventilated with positive-end expiratory pressure (PEEP), transthoracic needle biopsy was performed in 16 anesthetized mongrel dogs mechanically ventilated with 10 cm H2O of PEEP. To obtain the biopsy sample, a 25-gauge "skinny needle" was passed through a 20-gauge sheath and placed up to 6.25 cm deep. After satisfactory samples were obtained, both needles were withdrawn in the control group, but in the treated group, the outer sheath was used to inject 0.5 ml of isobutyl 2-cyanoacrylate to seal the needle track. Pneumothorax was present in 7 (87.5%) of 8 dogs in the control group and in 2 (25%) of 8 dogs in the treated group (p = .0147). Lung tissue exhibited an apparent foreign-body granulomatous inflammatory reaction. This technique could extend the benefits of transthoracic needle biopsy to mechanically ventilated patients, but further studies to prove the safety of isobutyl 2-cyanoacrylate are necessary.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3551860     DOI: 10.1016/s0003-4975(10)62816-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  CT-guided large-bore biopsy: extrapleural injection of saline for safe transpleural access to pulmonary lesions.

Authors:  K C Klose
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Jul-Aug       Impact factor: 2.740

2.  CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track.

Authors:  Christian Billich; Rainer Muche; Gerhard Brenner; Stefan A Schmidt; Stefan Krüger; Hans-Jürgen Brambs; Sandra Pauls
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

3.  Fibrin glue for sealing the needle track after percutaneous lung biopsy: Part I--Experimental study.

Authors:  T Petsas; P J Vassilakos; D Dougenis; C Giannakenas; C D Scopa; K Vasiou; I Fezoulidis
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Nov-Dec       Impact factor: 2.740

4.  Fibrin glue for sealing the needle track in fine-needle percutaneous lung biopsy using a coaxial system: Part II--Clinical study.

Authors:  T Petsas; D Siamblis; C Giannakenas; K Tepetes; D Dougenis; K Spiropoulos; I Fezoulis; I Dimopoulos
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Nov-Dec       Impact factor: 2.740

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.