Literature DB >> 18986903

Real-time 3-D ultrasound guidance of interventional devices.

Edward D Light1, John F Angle, Stephen W Smith.   

Abstract

We have previously developed 2-D array transducers for many real-time volumetric imaging applications. These applications include transducers operating up to 7 MHz for transthoracic imaging, up to 15 MHz for intracardiac echocardiography (ICE), 5 MHz for transesophageal echocardiography (TEE) and intracranial imaging, and 7 MHz for laparoscopic ultrasound imaging (LUS). Now we have developed a new generation of miniature ring-array transducers integrated into the catheter deployment kits of interventional devices to enable real-time 3-D ultrasound scanning for improved guidance of minimally invasive procedures. We have constructed 3 new ring transducers. The first consists of 54 elements operating at 5 MHz. Typical measured transducer element bandwidth was 25%, and the 50 Ohm round trip insertion loss was -65 dB. Average nearest neighbor cross talk was -23.8 dB. The second is a prototype 108-element transducer operating at 5 MHz. The third is a prototype 108-element ring array with a transducer center frequency of 8.9 MHz and a -6 dB bandwidth of 25%. All transducers were integrated with an 8.5 French catheter sheath of a Cook Medical, Inc. vena cava filter deployment device.

Entities:  

Mesh:

Year:  2008        PMID: 18986903      PMCID: PMC2656286          DOI: 10.1109/TUFFC.898

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

1.  Real-time three-dimensional dobutamine stress echocardiography in assessment stress echocardiography in assessment of ischemia: comparison with two-dimensional dobutamine stress echocardiography.

Authors:  M Ahmad; T Xie; M McCulloch; G Abreo; M Runge
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

2.  Real-time three-dimensional intracardiac echocardiography.

Authors:  E D Light; S F Idriss; P D Wolf; S W Smith
Journal:  Ultrasound Med Biol       Date:  2001-09       Impact factor: 2.998

3.  Real-time 3D transesophageal echocardiography.

Authors:  Eric C Pua; Salim F Idriss; Patrick D Wolf; S W Smith
Journal:  Ultrason Imaging       Date:  2004-10       Impact factor: 1.578

4.  Vena cava filters: do we know all that we need to know?

Authors:  Jack Ansell
Journal:  Circulation       Date:  2005-07-19       Impact factor: 29.690

Review 5.  Abdominal aortic aneurysm.

Authors:  Gilbert R Upchurch; Timothy A Schaub
Journal:  Am Fam Physician       Date:  2006-04-01       Impact factor: 3.292

6.  Real-time 3-d intracranial ultrasound with an endoscopic matrix array transducer.

Authors:  Edward D Light; Srinivasan Mukundan; Patrick D Wolf; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2007-05-03       Impact factor: 2.998

7.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

8.  Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts.

Authors:  Bart E Muhs; Eric L G Verhoeven; Clark J Zeebregts; Ignace F J Tielliu; Ted R Prins; Hence J M Verhagen; Jan J A M van den Dungen
Journal:  J Vasc Surg       Date:  2006-07       Impact factor: 4.268

Review 9.  Use of endoluminal aortic stent-grafts for the repair of abdominal aortic aneurysms.

Authors:  Maureen K Sheehan; Luke Marone; Michel S Makaroun
Journal:  Perspect Vasc Surg Endovasc Ther       Date:  2005-12

10.  Intravascular ultrasound-guided vena cava filter placement.

Authors:  W F Oppat; A C Chiou; J S Matsumura
Journal:  J Endovasc Surg       Date:  1999-08
View more
  4 in total

1.  New fabrication techniques for ring-array transducers for real-time 3D intravascular ultrasound.

Authors:  Edward D Light; Victor Lieu; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2009-10       Impact factor: 1.578

2.  Ring array transducers for real-time 3-D imaging of an atrial septal occluder.

Authors:  Edward D Light; Brooks D Lindsey; Joseph A Upchurch; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2012-06-12       Impact factor: 2.998

3.  Acoustic radiation force impulse imaging (ARFI) on an IVUS circular array.

Authors:  Vivek Patel; Jeremy J Dahl; David P Bradway; Joshua R Doherty; Seung Yun Lee; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

4.  Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Authors:  Ehud J Schmidt; Zion T H Tse; Tobias R Reichlin; Gregory F Michaud; Ronald D Watkins; Kim Butts-Pauly; Raymond Y Kwong; William Stevenson; Jeffrey Schweitzer; Israel Byrd; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.