Literature DB >> 11587457

Real-time three-dimensional echocardiography: an overview.

J A Panza1.   

Abstract

Conventional echocardiography and its representation of the heart in a two-dimensional format only provide partial information about cardiac function. Real-time three-dimensional echocardiography is a recently developed technique based on the design of an ultrasound transducer with a matrix array that instantaneously acquires the image contained in a pyramidal volume. The simultaneous display of multiple tomographic images allows the anatomically correct examination of any structure contained within the volumetric image. Software and technologies based on high performance computers designed for graphic handling of three-dimensional images permit the rapid mapping of the volumetric image and provide possibilities beyond those of the echograph. Using this methodology, it is possible to simultaneously visualize multiple superimposed planes in an interactive manner. Real-time three-dimensional echocardiography also allows a quantitative assessment of cardiac volumes, ventricular mass, and myocardium with contraction and/or perfusion abnormalities. This technique thus expands the abilities of non-invasive cardiology and may open new doors for the evaluation of cardiac disease.

Entities:  

Mesh:

Year:  2001        PMID: 11587457     DOI: 10.1023/a:1010669009889

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  8 in total

1.  Real-time three-dimensional echocardiography for measurement of left ventricular volumes.

Authors:  M A Schmidt; C J Ohazama; K O Agyeman; R Z Freidlin; M Jones; J M Laurienzo; C L Brenneman; A E Arai; O T von Ramm; J A Panza
Journal:  Am J Cardiol       Date:  1999-12-15       Impact factor: 2.778

Review 2.  Dynamic three-dimensional echocardiography: methods and clinical potential.

Authors:  N G Pandian; J Roelandt; N C Nanda; L Sugeng; Q L Cao; J Azevedo; S L Schwartz; M A Vannan; A Ludomirski; G Marx
Journal:  Echocardiography       Date:  1994-05       Impact factor: 1.724

3.  Three-dimensional spatial registration and interactive display of position and orientation of real-time ultrasound images.

Authors:  D L King; D L King; M Y Shao
Journal:  J Ultrasound Med       Date:  1990-09       Impact factor: 2.153

4.  Real time volumetric ultrasound imaging system.

Authors:  O T von Ramm; S W Smith
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

5.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering.

Authors:  S W Smith; H R Pavy; O T von Ramm
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

6.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display.

Authors:  O T von Ramm; S W Smith; H R Pavy
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

7.  A new integrated system for three-dimensional echocardiographic reconstruction: development and validation for ventricular volume with application in human subjects.

Authors:  M D Handschumacher; J P Lethor; S C Siu; D Mele; J M Rivera; M H Picard; A E Weyman; R A Levine
Journal:  J Am Coll Cardiol       Date:  1993-03-01       Impact factor: 24.094

8.  Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography.

Authors:  Gustavo Camarano; Michael Jones; Raisa Z Freidlin; Julio A Panza
Journal:  J Am Soc Echocardiogr       Date:  2002-03       Impact factor: 5.251

  8 in total
  3 in total

1.  Applications of 2-dimensional matrix array for 3- and 4-dimensional examination of the fetus: a pictorial essay.

Authors:  Luís F Gonçalves; Jimmy Espinoza; Juan Pedro Kusanovic; Wesley Lee; Jyh Kae Nien; Joaquin Santolaya-Forgas; Giancarlo Mari; Marjorie C Treadwell; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-06       Impact factor: 2.153

2.  Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography.

Authors:  Ashraf M Anwar; Marcel L Geleijnse; Osama I I Soliman; Jackie S McGhie; René Frowijn; Attila Nemes; Annemien E van den Bosch; Tjebbe W Galema; Folkert J Ten Cate
Journal:  Int J Cardiovasc Imaging       Date:  2007-02-23       Impact factor: 2.357

3.  M3VR-A multi-stage, multi-resolution, and multi-volumes-of-interest volume registration method applied to 3D endovaginal ultrasound.

Authors:  Qi Xing; Parag Chitnis; Siddhartha Sikdar; Jonia Alshiek; S Abbas Shobeiri; Qi Wei
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.