Literature DB >> 18265992

[Corneal topography. Analysis of the corneal surface].

C Herrmann1, U Ludwig, G Duncker.   

Abstract

Various diagnostic procedures have been developed for analyzing the corneal surface. Corneal topographical measurements can be performed by classic Placido disc topographers and tomographers creating three-dimensional corneal models from cross-sectional images. Using a slit scanning system or the Scheimpflug technique additional information about the anterior segment can be obtained. New systems give us a wide range of diagnostic tools. Beside the measurement of the corneal anterior and posterior surfaces and point-to-point-pachymetry they enable analysis of corneal aberrations and measurement of the whole anterior segment, including the anterior chamber and the position of implants, pupil diameter, horizontal white-to-white and the kappa angle. Densitometry, statistical programs for the evaluation of corneal pathology and assistance with intraocular lens calculation following excimer laser treatment are further options available. This article is intended to give an overview of the principles and limitations of the various diagnostic systems.

Entities:  

Mesh:

Year:  2008        PMID: 18265992     DOI: 10.1007/s00347-008-1696-0

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  17 in total

1.  Measuring central corneal thickness with ultrasound pachymetry.

Authors:  Tony Realini; Kim Lovelace
Journal:  Optom Vis Sci       Date:  2003-06       Impact factor: 1.973

Review 2.  [Current state of wavefront guided corneal surgery to correct refraction disorders].

Authors:  T Kohnen; J Bühren
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

Review 3.  Orbscan computerized topography: attributes, applications, and limitations.

Authors:  Gerard Cairns; Charles N J McGhee
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

4.  Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound.

Authors:  Birgit Lackner; Gerald Schmidinger; Stefan Pieh; Martin A Funovics; Christian Skorpik
Journal:  Optom Vis Sci       Date:  2005-10       Impact factor: 1.973

5.  [Central and peripheral corneal pachymetry--standard evaluation with the Pentacam system].

Authors:  F Rüfer; A Schröder; M-K Arvani; C Erb
Journal:  Klin Monbl Augenheilkd       Date:  2005-02       Impact factor: 0.700

Review 6.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

7.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part I: Basic principles].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-10       Impact factor: 1.059

Review 8.  Measuring the cornea: the latest developments in corneal topography.

Authors:  Tracy Swartz; Lisa Marten; Ming Wang
Journal:  Curr Opin Ophthalmol       Date:  2007-07       Impact factor: 3.761

9.  Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry.

Authors:  V Yaylali; S C Kaufman; H W Thompson
Journal:  J Cataract Refract Surg       Date:  1997-11       Impact factor: 3.351

Review 10.  [Image analysis and Sheimpflug photography of anterior segment of the eye--a review].

Authors:  A Wegener; H Laser
Journal:  Klin Monbl Augenheilkd       Date:  2001-02       Impact factor: 0.700

View more
  3 in total

1.  [Difference and distance between the central and thinnest points of the cornea: impact of refractive state, age and ocular side].

Authors:  J Steinberg; C Kohl; T Katz; G Richard; S J Linke
Journal:  Ophthalmologe       Date:  2014-04       Impact factor: 1.059

Review 2.  [Possibilities for use of Scheimpflug technology in cataract surgery].

Authors:  D M Handzel; C H Meyer; A Wegener
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

3.  Importance of fixation, pupil center, and reference axis in ocular wavefront sensing, videokeratography, and retinal image quality.

Authors:  Raymond A Applegate; Larry N Thibos; Michael D Twa; Edwin J Sarver
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.