Measuring central corneal thickness with ultrasound pachymetry.

Tony Realini1, Kim Lovelace.   

Abstract

PURPOSE: To determine how many ultrasound pachymetry measurements are required to obtain a reasonable estimate of central corneal thickness.
METHODS: Five central corneal thickness measurements were obtained from each eye of 101 patients with normal corneas. The means of fewer than five readings were compared with the mean of five values for each eye to determine the incremental clinical value of additional measurements.
RESULTS: Compared with the mean of five values, fewer than three measurements per eye provided a mean central corneal thickness value with inadequate confidence. Conversely, means of more than three readings provided little additional confidence over means of three values.
CONCLUSIONS: Central corneal thickness by ultrasound pachymetry can be adequately assessed in the majority of eyes by taking three measurements per eye.

Entities:  

Mesh:

Year:  2003        PMID: 12808403     DOI: 10.1097/00006324-200306000-00009

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease.

Authors:  A L Hoehn; S M Thomasy; P H Kass; T Horikawa; M Samuel; O R Shull; K A Stewart; C J Murphy
Journal:  Vet J       Date:  2018-10-30       Impact factor: 2.688

Review 2.  [Corneal topography. Analysis of the corneal surface].

Authors:  C Herrmann; U Ludwig; G Duncker
Journal:  Ophthalmologe       Date:  2008-02       Impact factor: 1.059

3.  Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography.

Authors:  Chixin Du; Jianhua Wang; Lele Cui; Meixiao Shen; Yimin Yuan
Journal:  Cornea       Date:  2012-09       Impact factor: 2.651

4.  Reliability of RTVue, Visante, and slit-lamp adapted ultrasonic pachymetry for central corneal thickness measurement.

Authors:  Jin Pyo Hong; Sang Min Nam; Tae-Im Kim; Kyoung Yul Seo; Sang Yeop Lee; Alessandro Meduri; Eung Kweon Kim
Journal:  Yonsei Med J       Date:  2012-05       Impact factor: 2.759

5.  Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.

Authors:  Jorge A Calvo-Sanz; Javier Ruiz-Alcocer; Miguel A Sánchez-Tena
Journal:  J Optom       Date:  2017-02-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.