Literature DB >> 18263955

Image reconstruction for fan-beam differential phase contrast computed tomography.

Guang-Hong Chen1, Zhihua Qi.   

Abstract

Recently, x-ray differential phase contrast computed tomography (DPC-CT) has been experimentally implemented using a conventional tube combined with gratings. Images were reconstructed using a parallel-beam reconstruction formula. However, parallel-beam reconstruction formulae are not applicable when the parallel-beam approximation fails. In this paper, we present a new image reconstruction formula for fan-beam DPC-CT. There are several novel features of the new image reconstruction formula: (i) when the scanning angular range of data acquisition is larger than pi + gamma(m) (gamma(m) is the full fan angle), the entire field of view can be exactly reconstructed; (ii) when the scanning angular range is smaller than pi + gamma(m), a local region of interest (ROI) can be exactly reconstructed; (iii) it enables an exact reconstruction for a local ROI when the projection data are truncated at some view angles; (iv) it enlarges the imaging field of view when the detector is asymmetrically placed. In this last case, the data are truncated from every view angle. Numerical simulations have been conducted to validate the new reconstruction formula.

Mesh:

Year:  2008        PMID: 18263955      PMCID: PMC2712659          DOI: 10.1088/0031-9155/53/4/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method.

Authors:  F A Dilmanian; Z Zhong; B Ren; X Y Wu; L D Chapman; I Orion; W C Thomlinson
Journal:  Phys Med Biol       Date:  2000-04       Impact factor: 3.609

2.  Three-dimensional beam-deflection optical tomography of a supersonic jet.

Authors:  G W Faris; R L Byer
Journal:  Appl Opt       Date:  1988-12-15       Impact factor: 1.980

3.  Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Authors:  Xiaochuan Pan; Yu Zou; Dan Xia
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

4.  Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.

Authors:  Shuai Leng; Tingliang Zhuang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Neutron phase imaging and tomography.

Authors:  F Pfeiffer; C Grünzweig; O Bunk; G Frei; E Lehmann; C David
Journal:  Phys Rev Lett       Date:  2006-06-02       Impact factor: 9.161

6.  Reconstruction of the refractive index gradient by x-ray diffraction enhanced computed tomography.

Authors:  Junyue Wang; Peiping Zhu; Qingxi Yuan; Wanxia Huang; Hang Shu; Bo Chen; Tiandou Hu; Ziyu Wu
Journal:  Phys Med Biol       Date:  2006-06-26       Impact factor: 3.609

7.  X-ray phase imaging with a grating interferometer.

Authors:  Timm Weitkamp; Ana Diaz; Christian David; Franz Pfeiffer; Marco Stampanoni; Peter Cloetens; Eric Ziegler
Journal:  Opt Express       Date:  2005-08-08       Impact factor: 3.894

8.  A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2007-09-04       Impact factor: 3.609

9.  Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.

Authors:  Tingliang Zhuang; Shuai Leng; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2004-12-21       Impact factor: 3.609

10.  Phase-contrast X-ray computed tomography for observing biological soft tissues.

Authors:  A Momose; T Takeda; Y Itai; K Hirano
Journal:  Nat Med       Date:  1996-04       Impact factor: 53.440

View more
  5 in total

1.  Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT.

Authors:  Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Grating-based phase contrast tomosynthesis imaging: proof-of-concept experimental studies.

Authors:  Ke Li; Yongshuai Ge; John Garrett; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

3.  Interior tomography in x-ray differential phase contrast CT imaging.

Authors:  Pascal Thériault Lauzier; Zhihua Qi; Joseph Zambelli; Nicholas Bevins; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

4.  X-ray phase sensitive imaging methods: basic physical principles and potential medical applications.

Authors:  Guang-Hong Chen; Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Ke Li
Journal:  Curr Med Imaging Rev       Date:  2010-05-01

5.  Explicit Filtering Based Low-Dose Differential Phase Reconstruction Algorithm with the Grating Interferometry.

Authors:  Xiaolei Jiang; Li Zhang; Ran Zhang; Hongxia Yin; Zhenchang Wang
Journal:  Comput Math Methods Med       Date:  2015-05-18       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.