Literature DB >> 10795982

Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method.

F A Dilmanian1, Z Zhong, B Ren, X Y Wu, L D Chapman, I Orion, W C Thomlinson.   

Abstract

Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al, in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry.

Entities:  

Mesh:

Year:  2000        PMID: 10795982     DOI: 10.1088/0031-9155/45/4/309

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

1.  Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT.

Authors:  Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometerand a rotating anode x-ray tube:theory and experiments.

Authors:  Guang-Hong Chen; Nicholas Bevins; Joseph Zambelli; Zhihua Qi
Journal:  Opt Express       Date:  2010-06-07       Impact factor: 3.894

3.  Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging.

Authors:  Yang Yu; Ruola Ning; Weixing Cai
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-03-16

4.  Image reconstruction for fan-beam differential phase contrast computed tomography.

Authors:  Guang-Hong Chen; Zhihua Qi
Journal:  Phys Med Biol       Date:  2008-01-24       Impact factor: 3.609

5.  Performance Investigation of a Hospital-grade X-ray Tube-based Differential Phase-contrast Cone Beam CT System.

Authors:  Yang Yu; Ruola Ning; Weixing Cai; Jiangkun Liu; David Conover
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-12

6.  On the possibility of quantitative refractive-index tomography of large biomedical samples with hard X-rays.

Authors:  Sergei Gasilov; Alberto Mittone; Emmanuel Brun; Alberto Bravin; Susanne Grandl; Paola Coan
Journal:  Biomed Opt Express       Date:  2013-08-02       Impact factor: 3.732

7.  Computer-aided diagnosis for phase-contrast X-ray computed tomography: quantitative characterization of human patellar cartilage with high-dimensional geometric features.

Authors:  Mahesh B Nagarajan; Paola Coan; Markus B Huber; Paul C Diemoz; Christian Glaser; Axel Wismüller
Journal:  J Digit Imaging       Date:  2014-02       Impact factor: 4.056

8.  Analyzer-based imaging technique in tomography of cartilage and metal implants: a study at the ESRF.

Authors:  Paola Coan; Juergen Mollenhauer; Andreas Wagner; Carol Muehleman; Alberto Bravin
Journal:  Eur J Radiol       Date:  2008-06-26       Impact factor: 3.528

Review 9.  Potential for imaging engineered tissues with X-ray phase contrast.

Authors:  Alyssa Appel; Mark A Anastasio; Eric M Brey
Journal:  Tissue Eng Part B Rev       Date:  2011-08-02       Impact factor: 6.389

10.  Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens.

Authors:  Masami Ando; Naoki Sunaguchi; Yanlin Wu; Synho Do; Yongjin Sung; Abner Louissaint; Tetsuya Yuasa; Shu Ichihara; Rajiv Gupta
Journal:  Eur Radiol       Date:  2013-09-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.