Literature DB >> 15815097

Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.

Shuai Leng1, Tingliang Zhuang, Brian E Nett, Guang-Hong Chen.   

Abstract

In this paper, we present a new algorithm designed for a specific data truncation problem in fan-beam CT. We consider a scanning configuration in which the fan-beam projection data are acquired from an asymmetrically positioned half-sized detector. Namely, the asymmetric detector only covers one half of the scanning field of view. Thus, the acquired fan-beam projection data are truncated at every view angle. If an explicit data rebinning process is not invoked, this data acquisition configuration will reek havoc on many known fan-beam image reconstruction schemes including the standard filtered backprojection (FBP) algorithm and the super-short-scan FBP reconstruction algorithms. However, we demonstrate that a recently developed fan-beam image reconstruction algorithm which reconstructs an image via filtering a backprojection image of differentiated projection data (FBPD) survives the above fan-beam data truncation problem. Namely, we may exactly reconstruct the whole image object using the truncated data acquired in a full scan mode (2pi angular range). We may also exactly reconstruct a small region of interest (ROI) using the truncated projection data acquired in a short-scan mode (less than 2pi angular range). The most important characteristic of the proposed reconstruction scheme is that an explicit data rebinning process is not introduced. Numerical simulations were conducted to validate the new reconstruction algorithm.

Mesh:

Year:  2005        PMID: 15815097     DOI: 10.1088/0031-9155/50/8/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Image reconstruction for fan-beam differential phase contrast computed tomography.

Authors:  Guang-Hong Chen; Zhihua Qi
Journal:  Phys Med Biol       Date:  2008-01-24       Impact factor: 3.609

2.  Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT--a preliminary study.

Authors:  Lingyun Chen; Chris C Shaw; Mustafa C Altunbas; Chao-Jen Lai; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

3.  Interior micro-CT with an offset detector.

Authors:  Kriti Sen Sharma; Hao Gong; Omid Ghasemalizadeh; Hengyong Yu; Ge Wang; Guohua Cao
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

4.  Interior tomography in x-ray differential phase contrast CT imaging.

Authors:  Pascal Thériault Lauzier; Zhihua Qi; Joseph Zambelli; Nicholas Bevins; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

5.  Half-Fan-Based Intensity-Weighted Region-of-Interest Imaging for Low-Dose Cone-Beam CT in Image-Guided Radiation Therapy.

Authors:  Boyeol Yoo; Kihong Son; Rizza Pua; Jinsung Kim; Alexander Solodov; Seungryong Cho
Journal:  Healthc Inform Res       Date:  2016-10-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.