Lung damage assessment from exposure to pulsed-wave ultrasound in the rabbit, mouse, and pig.

W R O'Brien1, J F Zachary.   

Abstract

The principal motivation of the study was to assess experimentally the question: "Is the MI (Mechanical Index) an equivalent or better indicator of nonthermal bioeffect risk than I(SPPA.3) (derated spatial peak, pulse average intensity)?" To evaluate this question, the experimental design consisted of a reproducible biological effect in order to provide a quantitative assessment of the effect. The specific biological effect used was lung damage and the species chosen was the rabbit. This work was initiated, in part, by a study in which lung hemorrhage was observed in 7-week old C3H mice for diagnostic-type, pulsed-wave ultrasound exposures, and, therefore, 6- to 7-week old C3H mice were used in this study as positive controls. Forty-seven adult New Zealand White male rabbits were exposed to a wide range of ultrasound amplitude conditions at center frequencies of 3 and 6 MHz with all temporal exposure variables held constant. A calibrated, commercial diagnostic ultrasound system was used as the ultrasound source with output levels exceeding, in some cases, permissible FDA levels. The MI was shown to be at least an equivalent, and in some cases, a better indicator of rabbit lung damage than either the I(SPPA.3) or p(r.3) (derated peak rarefactional pressure), thus answering the posed question positively. Further, in situ exposure conditions were estimated at the lung pleural surface (PS); the estimated in situ I(SPPA.PS) and p(r.PS) exposure conditions tracked lung damage no better than I(SPPA.3) and p(r.3), respectively, whereas the estimated in situ MI(PS) exposure condition was a slightly poorer predictor of lung damage than MI. Finally, the lungs of six adult crossbred pigs were exposed at the highest amplitude exposure levels permitted by a diagnostic ultrasound system (to prevent probe damage) at both frequencies; no lung damage was observed which suggests the possibility of a species dependency biological effect.

Entities:  

Year:  1997        PMID: 18244145     DOI: 10.1109/58.585132

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

6.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

Authors:  William D O'Brien; Douglas G Simpson; Leon A Frizzell; James F Zachary
Journal:  J Ultrasound Med       Date:  2006-07       Impact factor: 2.153

7.  Threshold estimation and superthreshold behavior of ultrasound-induced lung hemorrhage in rats: role of age dependency.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson
Journal:  Ultrasound Med Biol       Date:  2008-09-03       Impact factor: 2.998

8.  Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit.

Authors:  Zahra Izadifar; George Belev; Paul Babyn; Dean Chapman
Journal:  Biomed Eng Online       Date:  2015-10-19       Impact factor: 2.819

9.  Molecular and histological effects of MR-guided pulsed focused ultrasound to the rat heart.

Authors:  Kee W Jang; Tsang-Wei Tu; Matthew E Nagle; Bobbi K Lewis; Scott R Burks; Joseph A Frank
Journal:  J Transl Med       Date:  2017-12-13       Impact factor: 5.531

10.  Estimation of the acoustic impedance of lung versus level of inflation for different species and ages of animals.

Authors:  Michael L Oelze; Rita J Miller; James P Blue; James F Zachary; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2008-10       Impact factor: 2.482

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.