Literature DB >> 19690831

[Cost analysis for navigation in knee endoprosthetics].

O Cerha1, S Kirschner, K-P Günther, J Lützner.   

Abstract

BACKGROUND: Total knee arthroplasty (TKA) is one of the most frequent procedures in orthopaedic surgery. The outcome depends on a range of factors including alignment of the leg and the positioning of the implant in addition to patient-associated factors. Computer-assisted navigation systems can improve the restoration of a neutral leg alignment. This procedure has been established especially in Europe and North America. The additional expenses are not reimbursed in the German DRG system (Diagnosis Related Groups). In the present study a cost analysis of computer-assisted TKA compared to the conventional technique was performed.
METHODS: The acquisition expenses of various navigation systems (5 and 10 year depreciation), annual costs for maintenance and software updates as well as the accompanying costs per operation (consumables, additional operating time) were considered. The additional operating time was determined on the basis of a meta-analysis according to the current literature. Situations with 25, 50, 100, 200 and 500 computer-assisted TKAs per year were simulated.
RESULTS: The amount of the incremental costs of the computer-assisted TKA depends mainly on the annual volume and the additional operating time. A relevant decrease of the incremental costs was detected between 50 and 100 procedures per year. In a model with 100 computer-assisted TKAs per year an additional operating time of 14 mins and a 10 year depreciation of the investment costs, the incremental expenses amount to <euro> 300-395 depending on the navigation system.
CONCLUSIONS: Computer-assisted TKA is associated with additional costs. From an economical point of view an amount of more than 50 procedures per year appears to be favourable. The cost-effectiveness could be estimated if long-term results will show a reduction of revisions or a better clinical outcome.

Entities:  

Mesh:

Year:  2009        PMID: 19690831     DOI: 10.1007/s00132-009-1473-z

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  34 in total

1.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

2.  Alignments and clinical results in conventional and navigated total knee arthroplasty.

Authors:  A Ensini; F Catani; A Leardini; M Romagnoli; S Giannini
Journal:  Clin Orthop Relat Res       Date:  2007-04       Impact factor: 4.176

3.  Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres.

Authors:  Jean-Yves Jenny; Rolf K Miehlke; Alexander Giurea
Journal:  Knee       Date:  2008-02-11       Impact factor: 2.199

4.  Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation.

Authors:  J Lützner; F Krummenauer; C Wolf; K-P Günther; S Kirschner
Journal:  J Bone Joint Surg Br       Date:  2008-08

5.  The clinical consequences of flexion gap asymmetry in total knee arthroplasty.

Authors:  Jose Romero; Thomas Stähelin; Chistoph Binkert; Christian Pfirrmann; Jurg Hodler; Oliver Kessler
Journal:  J Arthroplasty       Date:  2007-02       Impact factor: 4.757

6.  [Rotational malalignment causing patellofemoral complications after total knee replacement].

Authors:  Ji-wei Luo; Cun-tai Yu; Jian Qin; Da-chuan Xu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2006-02

Review 7.  [Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies].

Authors:  H Bäthis; S Shafizadeh; T Paffrath; C Simanski; J Grifka; C Lüring
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

8.  Embolic phenomena during computer-assisted and conventional total knee replacement.

Authors:  J S Church; J E Scadden; R R Gupta; C Cokis; K A Williams; G C Janes
Journal:  J Bone Joint Surg Br       Date:  2007-04

9.  [Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty].

Authors:  S Hofmann; J Romero; E Roth-Schiffl; T Albrecht
Journal:  Orthopade       Date:  2003-06       Impact factor: 1.087

10.  The cost-effectiveness of computer-assisted navigation in total knee arthroplasty.

Authors:  Erik J Novak; Marc D Silverstein; Kevin J Bozic
Journal:  J Bone Joint Surg Am       Date:  2007-11       Impact factor: 5.284

View more
  8 in total

1.  Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study.

Authors:  Jörg Lützner; Klaus-Peter Günther; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-05       Impact factor: 4.342

2.  Intraoperative radiographs for placing acetabular components in hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu; Lee Webb
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

4.  Encouraging treatment algorithm for computer-assisted navigated total knee arthroplasty (TKA): A retrospective cohort analysis.

Authors:  J Cip; M Widemschek; C Bach; P Ruckenstuhl; T Benesch; K Studer; A Martin
Journal:  J Orthop       Date:  2017-06-24

5.  No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study.

Authors:  Jörg Lützner; Julian Dexel; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-14       Impact factor: 4.342

6.  Robotic-assisted TKA reduces surgery duration, length of stay and 90-day complication rate of complex TKA to the level of noncomplex TKA.

Authors:  Ricarda Stauss; Peter Savov; Lars-René Tuecking; Henning Windhagen; Max Ettinger
Journal:  Arch Orthop Trauma Surg       Date:  2022-10-14       Impact factor: 2.928

7.  Comparative Cost Analysis of Four Different Computer-Assisted Technologies to Implant a Total Knee Arthroplasty over Conventional Instrumentation.

Authors:  Bernhard Christen; Lars Tanner; Max Ettinger; Michel P Bonnin; Peter P Koch; Tilman Calliess
Journal:  J Pers Med       Date:  2022-01-30

8.  Intraoperative fluoroscopy improves surgical precision in conventional TKA.

Authors:  Hervé Hourlier; Peter Fennema
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-22       Impact factor: 4.342

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.