Literature DB >> 19994543

Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography.

MingDe Lin1, Craig T Marshall, Yi Qi, Samuel M Johnston, Cristian T Badea, Claude A Piantadosi, G Allan Johnson.   

Abstract

PURPOSE: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia.
METHODS: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100 x 100 microm2).
RESULTS: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0 +/- 5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90 x CODSA = COFick.
CONCLUSIONS: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

Entities:  

Mesh:

Year:  2009        PMID: 19994543      PMCID: PMC2780468          DOI: 10.1118/1.3231823

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  47 in total

1.  Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECT.

Authors:  R Wirestam; E Ryding; A Lindgren; B Geijer; S Holtås; F Ståhlberg
Journal:  MAGMA       Date:  2000-12       Impact factor: 2.310

2.  A maximum entropy method to compute the 13NH3 pulmonary transit time from right to left ventricle in cardiac PET studies.

Authors:  Stig Steenstrup; Jens D Hove; Klaus Kofoed; Henning Kelbaek
Journal:  Physiol Meas       Date:  2002-02       Impact factor: 2.833

3.  Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

Authors:  F Calamante; D G Gadian; A Connelly
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

4.  Vessel size measurements in angiograms: a comparison of techniques.

Authors:  Kenneth R Hoffmann; Daryl P Nazareth; László Miskolczi; Anant Gopal; Zhou Wang; Stephen Rudin; Daniel R Bednarek
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

5.  CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke.

Authors:  James D Eastwood; Michael H Lev; Tarek Azhari; Ting-Yim Lee; Daniel P Barboriak; David M Delong; Clemens Fitzek; Michael Herzau; Max Wintermark; Reto Meuli; David Brazier; James M Provenzale
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

6.  Measurement of the distribution of cardiac output in unanesthetized rats.

Authors:  Y Sasaki; H N Wagner
Journal:  J Appl Physiol       Date:  1971-06       Impact factor: 3.531

7.  Perfusion mapping using computed tomography allows accurate prediction of cerebral infarction in experimental brain ischemia.

Authors:  D G Nabavi; A Cenic; S Henderson; A W Gelb; T Y Lee
Journal:  Stroke       Date:  2001-01       Impact factor: 7.914

8.  New method of cardiac output measurement using ultrasound velocity dilution in rats.

Authors:  N Veal; F Moal; J Wang; E Vuillemin; F Oberti; E Roy; M Kaassis; R Trouvé; J L Saumet; P Calès
Journal:  J Appl Physiol (1985)       Date:  2001-09

9.  Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics.

Authors:  Fernando Calamante; Peter J Yim; Juan R Cebral
Journal:  Neuroimage       Date:  2003-06       Impact factor: 6.556

10.  Measurement of hepatocellular function, cardiac output, effective blood volume, and oxygen saturation in rats.

Authors:  J G Hauptman; G K DeJong; K A Blasko; I H Chaudry
Journal:  Am J Physiol       Date:  1989-08
View more
  12 in total

Review 1.  Applications of imaging technology in radiation research.

Authors:  MingDe Lin; Edward F Jackson
Journal:  Radiat Res       Date:  2012-03-08       Impact factor: 2.841

2.  Transpulmonary lactate shuttle.

Authors:  Matthew L Johnson; Chi-An W Emhoff; Michael A Horning; George A Brooks
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2011-10-26       Impact factor: 3.619

3.  A method for serial selective arterial catheterization and digital subtraction angiography in rodents.

Authors:  A Buhalog; R Yasuda; D Consigny; K Maurer; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-20       Impact factor: 3.825

4.  Analysis of the influence of 4D MR angiography temporal resolution on time-to-peak estimation error for different cerebral vessel structures.

Authors:  N D Forkert; T Illies; D Möller; H Handels; D Säring; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

5.  In vivo imaging of rat coronary arteries using bi-plane digital subtraction angiography.

Authors:  Cristian T Badea; Laurence W Hedlund; Yi Qi; Brian Berridge; G Allan Johnson
Journal:  J Pharmacol Toxicol Methods       Date:  2011-06-13       Impact factor: 1.950

6.  Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography.

Authors:  MingDe Lin; Yi Qi; Antonia F Chen; Cristian T Badea; G Allan Johnson
Journal:  J Pharmacol Toxicol Methods       Date:  2011-08-07       Impact factor: 1.950

7.  In vivo X-ray digital subtraction and CT angiography of the murine cerebrovasculature using an intra-arterial route of contrast injection.

Authors:  G Figueiredo; H Boll; M Kramer; C Groden; M A Brockmann
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

Review 8.  Data science of stroke imaging and enlightenment of the penumbra.

Authors:  Fabien Scalzo; May Nour; David S Liebeskind
Journal:  Front Neurol       Date:  2015-03-05       Impact factor: 4.003

Review 9.  In vivo small animal micro-CT using nanoparticle contrast agents.

Authors:  Jeffrey R Ashton; Jennifer L West; Cristian T Badea
Journal:  Front Pharmacol       Date:  2015-11-04       Impact factor: 5.810

10.  A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

Authors:  Cristian T Badea; Laurence W Hedlund; G Allan Johnson
Journal:  J Med Eng       Date:  2013-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.