Literature DB >> 31180845

Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT.

Luyao Shi, Yihuan Lu, Jing Wu, Jean-Dominique Gallezot, Nabil Boutagy, Stephanie Thorn, Albert J Sinusas, Richard E Carson, Chi Liu.   

Abstract

Recently introduced stationary dedicated cardiac SPECT scanners provide new opportunities to quantify myocardial blood flow (MBF) using dynamic SPECT. However, comparing to PET, the low sensitivity of SPECT scanners affects MBF quantification due to the high noise level, especially for 201 Thallium (201Tl) due to its typically low injected dose. The conventional indirect method for generating parametric images typically starts by reconstructing a time series of frame images followed by fitting the time-activity curve (TAC) for each voxel or segment with an appropriate kinetic model. The indirect method is simple and easy to implement; however, it usually suffers from substantial image noise that could also lead to bias. In this paper, we developed a list mode direct parametric image reconstruction algorithm to substantially reduce noise in MBF quantification using dynamic SPECT and allow for patient radiation dose reduction. GPU-based parallel computing was used to achieve more than 2000-fold acceleration. The proposed method was evaluated in both simulation and in vivo canine studies. Compared with the indirect method, the proposed direct method achieved substantially lower image noise and variability, particularly at large number of iterations and at low-count levels.

Entities:  

Mesh:

Year:  2019        PMID: 31180845      PMCID: PMC7030971          DOI: 10.1109/TMI.2019.2921969

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  38 in total

1.  Noise properties of the EM algorithm: II. Monte Carlo simulations.

Authors:  D W Wilson; B M Tsui; H H Barrett
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

2.  Optimization algorithms and weighting factors for analysis of dynamic PET studies.

Authors:  Maqsood Yaqub; Ronald Boellaard; Marc A Kropholler; Adriaan A Lammertsma
Journal:  Phys Med Biol       Date:  2006-08-08       Impact factor: 3.609

3.  Maximum a posteriori reconstruction of the Patlak parametric image from sinograms in dynamic PET.

Authors:  Guobao Wang; Lin Fu; Jinyi Qi
Journal:  Phys Med Biol       Date:  2008-01-10       Impact factor: 3.609

4.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels.

Authors:  Mary Germino; Jean-Dominque Gallezot; Jianhua Yan; Richard E Carson
Journal:  Phys Med Biol       Date:  2017-05-15       Impact factor: 3.609

6.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

7.  Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET.

Authors:  Tiziano Schepis; Oliver Gaemperli; Valerie Treyer; Ines Valenta; Cyrill Burger; Pascal Koepfli; Mehdi Namdar; Itaru Adachi; Hatem Alkadhi; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2007-10-17       Impact factor: 10.057

Review 8.  Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?

Authors:  Robert A deKemp; Keiichiro Yoshinaga; Rob S B Beanlands
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

9.  Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET.

Authors:  Yihuan Lu; Jean-Dominique Gallezot; Mika Naganawa; Silin Ren; Kathryn Fontaine; Jing Wu; John A Onofrey; Takuya Toyonaga; Nabil Boutagy; Tim Mulnix; Vladimir Y Panin; Michael E Casey; Richard E Carson; Chi Liu
Journal:  Phys Med Biol       Date:  2019-03-08       Impact factor: 3.609

Review 10.  Direct estimation of kinetic parametric images for dynamic PET.

Authors:  Guobao Wang; Jinyi Qi
Journal:  Theranostics       Date:  2013-11-20       Impact factor: 11.556

View more
  3 in total

1.  Quantitative Assessment of Myocardial Ischemia With Positron Emission Tomography.

Authors:  Jae Ho Sohn; Spencer C Behr; Miguel Hernandez Pampaloni; Youngho Seo
Journal:  J Thorac Imaging       Date:  2021-01-22       Impact factor: 5.528

2.  Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition.

Authors:  Yoonsuk Huh; Uttam M Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Front Cardiovasc Med       Date:  2022-07-13

3.  Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning.

Authors:  Luyao Shi; Yihuan Lu; Nicha Dvornek; Christopher A Weyman; Edward J Miller; Albert J Sinusas; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.