Quantitative PET with positron emitters that emit prompt gamma rays.

C C Martin1, B T Christian, M R Satter, L H Nickerson, R J Nickles.   

Abstract

The purpose of this work was to determine the feasibility of using positron emitting isotopes that emit prompt gammas to acquire quantitative positron emission tomography (PET) data using standard PET instrumentation. Prompt gammas can contaminate PET data by increasing dead time, converting singles into invalid coincidences, and producing multiple coincidences which can lead to the replacement of valid coincidences by invalid coincidences. The measurements in this work were made by scanning point sources containing F-18, Na-22, and Co-60 and studying the effects of the prompt gammas on the PET data, We found that for the Na-22 point source, the annihilation photon coincidence rate was about 25 times the prompt gamma-annihilation photon coincidence rate in the entire active volume of the scanner. With scatter, the Na-22 prompt gamma-annihilation photon coincidence rate was 1.3 times higher than the F-18 scatter coincidence rate. The most significant effect of the prompt gamma was to increase dead time; the dead time correction factor for Cu-60 was 2.4 times higher than the correction factor for N-13 for the same source activity. We conclude that, in many cases, quantitative PET data can be readily obtained with isotopes that emit prompt gammas, using standard PET 2-D instrumentation. However there are some cases, such as 3-D PET, where prompt gammas could significantly contaminate the PET data.

Entities:  

Year:  1995        PMID: 18215872     DOI: 10.1109/42.476109

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  Effect of partition coefficient, permeability surface product, and radioisotope on the signal-to-noise ratio in PET functional brain mapping: a computer simulation.

Authors:  C C Martin; P A Jerabek; L D Nickerson; P T Fox
Journal:  Hum Brain Mapp       Date:  1999       Impact factor: 5.038

Review 2.  Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Authors:  Roberto Sciagrà; Alessandro Passeri; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Alessia Gimelli; Fabien Hyafil; Denis Agostini; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-02-05       Impact factor: 9.236

Review 3.  Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective.

Authors:  Jonathan B Moody; Benjamin C Lee; James R Corbett; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2015-04-14       Impact factor: 5.952

Review 4.  Quantitative imaging of 124I and 86Y with PET.

Authors:  Mark Lubberink; Hans Herzog
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

5.  Development of a novel linearly-filled Derenzo microPET phantom.

Authors:  Benjamin L Cox; Stephen A Graves; Mohammed Farhoud; Todd E Barnhart; Justin J Jeffery; Kevin W Eliceiri; Robert J Nickles
Journal:  Am J Nucl Med Mol Imaging       Date:  2016-07-06

6.  Dependency of cardiac rubidium-82 imaging quantitative measures on age, gender, vascular territory, and software in a cardiovascular normal population.

Authors:  John J Sunderland; Xiao-Bo Pan; Jerome Declerck; Yusuf Menda
Journal:  J Nucl Cardiol       Date:  2014-10-08       Impact factor: 5.952

7.  Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT.

Authors:  Fabio P Esteves; Jonathan A Nye; Akbar Khan; Russell D Folks; Raghuveer K Halkar; Ernest V Garcia; David M Schuster; Stamatios Lerakis; Paolo Raggi; John R Votaw
Journal:  J Nucl Cardiol       Date:  2009-11-24       Impact factor: 5.952

8.  Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86.

Authors:  Stéphan Walrand; François Jamar; Isabelle Mathieu; Joëlle De Camps; Max Lonneux; Mérence Sibomana; Daniel Labar; Christian Michel; Stanislas Pauwels
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-12-17       Impact factor: 9.236

9.  dAcquisition setting optimization and quantitative imaging for 124I studies with the Inveon microPET-CT system.

Authors:  Nadège Anizan; Thomas Carlier; Cecilia Hindorf; Jacques Barbet; Manuel Bardiès
Journal:  EJNMMI Res       Date:  2012-02-13       Impact factor: 3.138

10.  Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI.

Authors:  Thorsten Heußer; Philipp Mann; Christopher M Rank; Martin Schäfer; Antonia Dimitrakopoulou-Strauss; Heinz-Peter Schlemmer; Boris A Hadaschik; Klaus Kopka; Peter Bachert; Marc Kachelrieß; Martin T Freitag
Journal:  PLoS One       Date:  2017-08-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.