Literature DB >> 1820314

Comparison of impression techniques for a five-implant mandibular model.

A B Carr1.   

Abstract

Production of an accurate dental cast framework that meets the implant objective of passive fit demands an understanding of potential processing errors. Working casts fabricated from impressions using two different transfer copings, as provided by a leading implant manufacturer, were investigated for differences in accuracy. A five-implant mandibular model was used to produce seven casts by both the indirect and direct transfer coping techniques. Comparison was made by using a dental cast framework fitted to the master cast. Differences in distances measured between each group and the master cast were analyzed to establish differences between methods. For the model used, the direct technique produced more accurate working casts. A concern for potential impression distortion given the specific clinical situation underscores the method of choice.

Mesh:

Substances:

Year:  1991        PMID: 1820314

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  24 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

Review 3.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

4.  Evaluation of accuracy of direct transfer snapon impression coping closed tray impression technique and direct transfer open tray impression technique: an in vitro study.

Authors:  T Balamurugan; P Manimaran
Journal:  J Indian Prosthodont Soc       Date:  2012-08-19

5.  Accuracy of a proposed implant impression technique using abutments and metal framework.

Authors:  Hyeok-Jae Lee; Young-Jun Lim; Chang-Whe Kim; Jung-Han Choi; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2010-03-31       Impact factor: 1.904

6.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

7.  Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study.

Authors:  Si-Hoon Jo; Kyoung-Il Kim; Jae-Min Seo; Kwang-Yeob Song; Ju-Mi Park; Seung-Geun Ahn
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

8.  Accuracy of five implant impression technique: effect of splinting materials and methods.

Authors:  Sang-Jik Lee; Sung-Bum Cho
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

9.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

10.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.