Literature DB >> 18193463

Use of Amplatzer Vascular Plug (AVP) in emergency embolisation: preliminary experience and review of literature.

Monica Mangini1, Domenico Laganà, Federico Fontana, Andrea Ianniello, Paolo Nicotera, Maria Petullà, Gianpaolo Carrafiello, Carlo Fugazzola.   

Abstract

Amplatzer Vascular Plug (AVP) is a device recently proposed for extra-cardiac procedures such as arterial and venous embolisation. In this paper, we assess the usefulness of AVP in emergency embolisation presenting our preliminary experience and reviewing the Literature. During the last year, we selected 31 patients for embolisation using AVP. The following nine procedures were performed in emergency (8 males, mean 72.4 years, range 57-85): four ruptured abdominal aortic aneurysm, one traumatic hepatic pseudoaneurysm with arterio-portal fistula, one carotid pseudoaneurysm due to neoplastic erosion, one renal tumor with active bleeding, one ruptured isolated iliac aneurysm and one ruptured hypogastric aneurysm. We used a total of 13 AVPs. The follow-up was carried out by computed tomography angiography (CTA) and/or contrast-enhanced ultrasound (CEUS), 3 months after the procedure and then every 3 months. We obtained immediate technical success in all nine cases. No rupture or dissection of the treated arteries occurred. We observed only an asymptomatic spasm. During a mean follow-up of 5.3 months (range 3-12 months), CTA and/or CEUS showed complete occlusion of the treated arteries. The AVP is useful in some emergency settings. In the authors' experience, the device allows precise, controlled release and can be deployed to the target more rapidly than other traditional methods. The device cannot be used in all patients due to limited ability to negotiate tortuous vessels and limited size availability. In our institution, the AVP is less expensive than alternatives. In our experience and as reported in the early literature, the device is easy to use, versatile, and achieved a high technical success rate. Further studies may confirm the effectiveness and demonstrate additional indications.

Entities:  

Mesh:

Year:  2008        PMID: 18193463     DOI: 10.1007/s10140-007-0696-8

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  25 in total

1.  Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device.

Authors:  Giuseppe Santoro; Maurizio Cappelli Bigazzi; Maria Teresa Palladino; Maria Giovanna Russo; Marianna Carrozza; Raffaele Calabrò
Journal:  Am J Cardiol       Date:  2004-07-15       Impact factor: 2.778

2.  Use of the Amplatzer Vascular Plug for embolization of a large retroperitoneal shunt during transjugular intrahepatic portosystemic shunt creation for gastric variceal bleeding.

Authors:  Jonathan Kessler; Scott O Trerotola
Journal:  J Vasc Interv Radiol       Date:  2006-01       Impact factor: 3.464

3.  Amplatzer Vascular Plug to occlude the internal iliac arteries in patients undergoing aortoiliac aneurysm repair.

Authors:  Chi D Ha; David Calcagno
Journal:  J Vasc Surg       Date:  2005-12       Impact factor: 4.268

4.  Initial clinical experience using the Amplatzer Vascular Plug.

Authors:  David J Tuite; David O Kessel; Anthony A Nicholson; Jai V Patel; Simon J McPherson; David R Shaw
Journal:  Cardiovasc Intervent Radiol       Date:  2007 Jul-Aug       Impact factor: 2.740

5.  Transcatheter closure of pulmonary arteriovenous malformations with amplatzer devices.

Authors:  Avi Beck; Tamir Dagan; Avraham Matitiau; Elchanan Bruckheimer
Journal:  Catheter Cardiovasc Interv       Date:  2006-06       Impact factor: 2.692

6.  Multimodal approach to endovascular treatment of visceral artery aneurysms and pseudoaneurysms.

Authors:  Domenico Laganà; Gianpaolo Carrafiello; Monica Mangini; Gianlorenzo Dionigi; Roberto Caronno; Patrizio Castelli; Carlo Fugazzola
Journal:  Eur J Radiol       Date:  2006-04-04       Impact factor: 3.528

7.  Percutaneous occlusion of a pulmonary aneurysm causing hemoptysis in a patient with pulmonary atresia and aortopulmonary collaterals.

Authors:  Gordon E Pate; Ronald G Carere
Journal:  Catheter Cardiovasc Interv       Date:  2005-06       Impact factor: 2.692

8.  Endovascular ligature of splenic artery aneurysm with Amplatzer Vascular Plug: a case report.

Authors:  Gianpaolo Carrafiello; Domenico Laganà; Massimiliano Dizonno; Monica Mangini; Carlo Fugazzola
Journal:  Cardiovasc Revasc Med       Date:  2007 Jul-Sep

9.  Successful closure of a giant true saphenous vein graft aneurysm using the Amplatzer vascular plug.

Authors:  Ilias Mylonas; Yoshihito Sakata; Michael H Salinger; Ted Feldman
Journal:  Catheter Cardiovasc Interv       Date:  2006-04       Impact factor: 2.692

10.  Dual use of an amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula.

Authors:  Oluwatoyin Idowu; Fayyaz Barodawala; Alexander Nemeth; Scott O Trerotola
Journal:  J Vasc Interv Radiol       Date:  2007-05       Impact factor: 3.464

View more
  12 in total

Review 1.  The Amplatzer Vascular Plug: Review of Evolution and Current Applications.

Authors:  Jorge E Lopera
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Use of an amplatzer vascular plug in embolization of a pulmonary artery aneurysm in a case of hughes-stovin syndrome: a case report.

Authors:  Vasileios D Tzilalis; Georgios Vourliotakis; Ioannis A Tsironis; Vasileios D Tsiligiris; Elias N Brountzos
Journal:  J Med Case Rep       Date:  2011-09-01

3.  Persistent postpartum haemorrhage after failed arterial ligation: value of pelvic embolisation.

Authors:  Yann Fargeaudou; Olivier Morel; Philippe Soyer; Etienne Gayat; Marc Sirol; Mourad Boudiaf; Henri Dahan; Emmanuel Barranger; Alexandre Mebazaa; Olivier le Dref
Journal:  Eur Radiol       Date:  2010-03-23       Impact factor: 5.315

4.  Double-barrel plugging in a recurrent aorto-enteric fistula.

Authors:  Anoop Ayyappan; Jineesh Valakkada; Mahesh Reddy Bursupalle; Santhosh Kumar Kannath; Shivanesan Pitchai
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2022-03-22

5.  Applications of the Amplatzer Vascular Plug to various vascular lesions.

Authors:  Serkan Güneyli; Celal Çinar; Halil Bozkaya; Mustafa Parıldar; İsmail Oran
Journal:  Diagn Interv Radiol       Date:  2014 Mar-Apr       Impact factor: 2.630

6.  Imaging guided percutaneous renal biopsy: do it or not?

Authors:  Francesco Pagnini; Eleonora Cervi; Umberto Maestroni; Andrea Agostini; Alessandra Borgheresi; Filippo Piacentino; Salvatore Alessio Angileri; Anna Maria Ierardi; Chiara Floridi; Mattia Carbone; Francesco Ziglioli; Massimo De Filippo
Journal:  Acta Biomed       Date:  2020-07-13

7.  Percutaneous needle biopsy of retroperitoneal lesions: technical developments.

Authors:  Andrea Bevilacqua; Fabiano Vito D'Amuri; Francesco Pagnini; Vittorio Sabatino; Umberto Russo; Nicola Maggialetti; Pierpaolo Palumbo; Silvia Pradella; Andrea Giovagnoni; Vittorio Miele; Massimo De Filippo
Journal:  Acta Biomed       Date:  2019-04-24

8.  Radiation-induced brain cavernomas in elderly: review of the literature and a rare case report.

Authors:  Giuseppe Mariniello; Maria De Liso; Camilla Russo; Walter Del Vecchio; Oreste De Divitiis; Federico Bruno; Nicola Maggialetti; Francesco Arrigoni; Luca Brunese; Ferdinando Caranci
Journal:  Acta Biomed       Date:  2019-04-24

9.  Transcatheter arterial embolization of acute bleeding as 24/7 service: predictors of outcome and mortality.

Authors:  Maciej Powerski; Philipp Meyer-Wilmes; Jazan Omari; Robert Damm; Max Seidensticker; Björn Friebe; Frank Fischbach; Maciej Pech
Journal:  Br J Radiol       Date:  2018-08-29       Impact factor: 3.039

Review 10.  Endoluminal occlusion devices: technology update.

Authors:  Tobias Zander; Samantha Medina; Guillermo Montes; Lourdes Nuñez-Atahualpa; Michel Valdes; Manuel Maynar
Journal:  Med Devices (Auckl)       Date:  2014-12-01
View more