Literature DB >> 24047719

Applications of the Amplatzer Vascular Plug to various vascular lesions.

Serkan Güneyli1, Celal Çinar, Halil Bozkaya, Mustafa Parıldar, İsmail Oran.   

Abstract

The Amplatzer® Vascular Plug (AVP) can be used to embolize medium-to-large high-flow vessels in various locations. Between 2009 and 2012, 41 AVPs (device size, 6-22 mm in diameter) were used to achieve occlusion in 31 patients (24 males, seven females) aged 9-92 years (mean age, 54.5 years). The locations and indications for embolotherapy were as follows: internal iliac artery embolization before stent-graft repair for aorto-iliac (n=6) and common iliac artery (n=3) aneurysms, subclavian artery embolization before stent-graft repair for thoracic aorta (n=3) and arcus aorta (n=1) aneurysms, brachiocephalic trunk embolization before stent-graft repair for a thoracic aorta aneurysm (n=1), embolization of aneurysms and pseudoaneurysms (n=5), embolization for carotid blow-out syndrome (n=3), closure of arteriovenous fistula (n=8), and closure of a portosystemic fistula (n=1). Of the 41 AVPs, 30 were AVP 2 and 11 were AVP 4. The mean follow-up duration was 4.7 months (range, 1-24 months). During follow-up, there was one migration, one insufficient embolization, and one recanalization. The remaining vascular lesions were successfully excluded from the circulation. The AVP, which can be used in a wide spectrum of pathologies, is easy to use and causes few complications. This essay presents our experience with the AVP.

Entities:  

Mesh:

Year:  2014        PMID: 24047719      PMCID: PMC4463302          DOI: 10.5152/dir.2013.13139

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  14 in total

1.  Endovascular treatment of a traumatic direct carotid-cavernous fistula using the Amplatzer Vascular Plug II.

Authors:  Pasquale Mordasini; Gerhard Schroth; Caspar Brekenfeld; Christian Fung; Hanno Hoppe; Jan Gralla
Journal:  J Endovasc Ther       Date:  2010-08       Impact factor: 3.487

2.  Transcatheter closure of patent ductus venosus with the Amplatzer vascular plug in twin brothers.

Authors:  M J Gillespie; A Golden; V B Sivarajan; J J Rome
Journal:  Pediatr Cardiol       Date:  2006 Jan-Feb       Impact factor: 1.655

3.  Evaluation of the AMPLATZER vascular plug for embolization of peripheral vascular malformations associated with congenital heart disease.

Authors:  S L Hill; Z M Hijazi; W E Hellenbrand; J P Cheatham
Journal:  Catheter Cardiovasc Interv       Date:  2006-01       Impact factor: 2.692

4.  Successful transcatheter closure of a large patent ductus venosus with the Amplatzer vascular plug II.

Authors:  Y K Cho; N-K Chang; J S Ma
Journal:  Pediatr Cardiol       Date:  2009-03-18       Impact factor: 1.655

5.  Applications of the Amplatzer Vascular Plug 4.

Authors:  Adalet Elçin Yıldız; Bora Peynircioğlu; Barbaros Erhan Cil
Journal:  Diagn Interv Radiol       Date:  2011-09-16       Impact factor: 2.630

6.  Use of the Amplatzer vascular plug as an anchoring scaffold for coil-mediated parent vessel occlusion: technical case report.

Authors:  Daniel A Hoit; Clemens M Schirmer; Adel M Malek
Journal:  Neurosurgery       Date:  2006-07       Impact factor: 4.654

7.  The Amplatzer vascular plug and Amplatzer vascular plug II for vascular occlusion procedures in 50 patients with congenital cardiovascular disease.

Authors:  Matthew Schwartz; Andrew C Glatz; Jonathan J Rome; Matthew J Gillespie
Journal:  Catheter Cardiovasc Interv       Date:  2010-09-01       Impact factor: 2.692

8.  Preoperative portal vein embolization using an amplatzer vascular plug.

Authors:  Hyunkyung Yoo; Gi-Young Ko; Dong Il Gwon; Jin-Hyoung Kim; Hyun-Ki Yoon; Kyu-Bo Sung; Namguk Kim; Jeongjin Lee
Journal:  Eur Radiol       Date:  2008-12-05       Impact factor: 5.315

9.  Transcatheter occlusion of pulmonary arteriovenous malformations using the Amplatzer Vascular Plug II.

Authors:  Nora E Tabori; Barry A Love
Journal:  Catheter Cardiovasc Interv       Date:  2008-06-01       Impact factor: 2.692

10.  Neuroapplication of amplatzer vascular plug for therapeutic sacrifice of major craniocerebral arteries: an initial clinical experience.

Authors:  Cheng Kang Ong; Dang V Lam; Michelle T Ong; Mark A Power; Richard J Parkinson; Jason D Wenderoth
Journal:  Ann Acad Med Singapore       Date:  2009-09       Impact factor: 2.473

View more
  6 in total

Review 1.  Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

Authors:  Sivasubramanian Ramakrishnan
Journal:  Indian Heart J       Date:  2015-07-26

2.  Delayed failure of rectovaginal fistula embolization with Amplatzer vascular plug 2.

Authors:  Özgür Kılıçkesmez; Cağatay Andıç; Levent Oğuzkurt
Journal:  Diagn Interv Radiol       Date:  2014-11       Impact factor: 2.630

3.  Splenic artery embolization with Ankaferd blood stopper in a sheep model.

Authors:  Osman Koç; Kadir Acar; Orhan Özbek; İbrahim Güler; Kadir Sarıtaş; Tuba Bera Erdem; Yalçın Solak; Hatice Toy; Ahmet Küçükapan; Seda Özbek; Abduzhappar Gaipov; İbrahim C Haznedaroğlu
Journal:  Diagn Interv Radiol       Date:  2016 Jul-Aug       Impact factor: 2.630

4.  A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft.

Authors:  Efstratios Georgakarakos; Andreas Koutsoumpelis; Panagiotis Kostoglou; Kalliopi-Maria Tasopoulou; Christos Argyriou
Journal:  Aorta (Stamford)       Date:  2022-05-31

5.  Amplatzer vascular plug as an embolic agent in different vascular pathologies: A pictorial essay.

Authors:  Jonathan Tresley; Shivank Bhatia; Issam Kably; Prasoon Poozhikunnath Mohan; Jason Salsamendi; Govindarajan Narayanan
Journal:  Indian J Radiol Imaging       Date:  2016 Apr-Jun

Review 6.  Endoluminal occlusion devices: technology update.

Authors:  Tobias Zander; Samantha Medina; Guillermo Montes; Lourdes Nuñez-Atahualpa; Michel Valdes; Manuel Maynar
Journal:  Med Devices (Auckl)       Date:  2014-12-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.