Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device.

Giuseppe Santoro1, Maurizio Cappelli Bigazzi, Maria Teresa Palladino, Maria Giovanna Russo, Marianna Carrozza, Raffaele Calabrò.   

Abstract

This study compared the efficacy and costs of the most used approaches for percutaneous closure of large patent ductus arteriosus, that is, multiple coils and the Amplatzer duct occluder (ADO) device. From April 2000 to September 2003, 47 patients underwent closure of large, symptomatic patent ductus arteriosus (diameter 4.6 +/- 3.0 mm/m(2); QP/QS 2.1 +/- 1.9) with multiple Cook detachable coils (n = 19) or the ADO device (n = 28). The multiple coil approach was significantly cheaper (1,389 +/- 168 vs 3,811 +/- 38, p <0.0001) but as effective as the ADO device over a mid-term follow-up (occlusion rate 89.5% vs 96.4%, p = NS).

Entities:  

Mesh:

Year:  2004        PMID: 15246917     DOI: 10.1016/j.amjcard.2004.03.079

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

Review 1.  Use of Amplatzer Vascular Plug (AVP) in emergency embolisation: preliminary experience and review of literature.

Authors:  Monica Mangini; Domenico Laganà; Federico Fontana; Andrea Ianniello; Paolo Nicotera; Maria Petullà; Gianpaolo Carrafiello; Carlo Fugazzola
Journal:  Emerg Radiol       Date:  2008-01-10

2.  Transcatheter amplatzer occlusion and surgical closure of patent ductus arteriosus: comparison of effectiveness and costs in a low-income country.

Authors:  Zhaoyang Chen; Lianglong Chen; Liming Wu
Journal:  Pediatr Cardiol       Date:  2009-04-14       Impact factor: 1.655

3.  Transcatheter closure of symptomatic arterial duct in infants younger than 1 year old.

Authors:  Biagio Castaldi; Giuseppe Santoro; Gianpiero Gaio; Maria Teresa Palladino; Carola Iacono; Maria Giovanna Russo
Journal:  Pediatr Cardiol       Date:  2012-05-26       Impact factor: 1.655

4.  Transcatheter closure of patent ductus arteriosus: Evaluating the effect of the learning curve on the outcome.

Authors:  Ahmad S Azhar; Ayman A Abd El-Azim; Hamed S Habib
Journal:  Ann Pediatr Cardiol       Date:  2009-01

5.  Indications for the use of the Amplatzer vascular plug in interventional radiology.

Authors:  D Laganà; G Carrafiello; M Mangini; D Lumia; F Fontana; A Ianniello; C Fugazzola
Journal:  Radiol Med       Date:  2008-07-01       Impact factor: 3.469

6.  Transcatheter Closure of Arterial Duct in Infants < 6 kg: Amplatzer Duct Occluder Type I vs Amplatzer Duct Occluder II Additional Sizes.

Authors:  Giuseppe Santoro; Mario Giordano; Gianpiero Gaio; Maria Teresa Palladino; Giovanbattista Capozzi; Carola Iacono; Maria Giovanna Russo
Journal:  Pediatr Cardiol       Date:  2018-02-17       Impact factor: 1.655

7.  Experience with percutaneous closure of ductus arteriosus using the Amplatzer duct occluder in 243 consecutive patients and long-term results-A single centre study.

Authors:  Mostafa Behjati-Ardakani; Mohammad Amin Behjati-Ardakani; Mehdi Hadadzadeh; Seyed Hossein Moshtaghion; Mohammadtaghi Sarebanhassanabadi
Journal:  Niger Med J       Date:  2014-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.