BACKGROUND AND PURPOSE: The Amplatzer Vascular Plug (AVP) is a self-expanding nitinol wire mesh vascular embolization device derived from the Amplatz septal occluder. We assessed the results of vascular embolization obtained using the AVP. METHODS: A retrospective review was carried out of 23 consecutive cases of vascular embolization using the AVP in a variety of different clinical settings. The AVP was chosen to have a diameter approximately 30-50% greater than the target vessel. The device was delivered via an appropriately sized guide catheter and was released when satisfactorily positioned. Additional embolic agents were used in some cases. RESULTS: All target vessels were successfully occluded with no device malpositioning or malfunction. In 14 (61%) patients the AVP was the sole embolic material. In the remaining patients additional agents were used, particularly in preoperative embolization of highly vascular renal tumors. The AVP does not cause instantaneous thrombosis and in high-flow situations thrombosis typically takes up to 15 min. CONCLUSION: The AVP is a safe, effective embolization device that provides a useful adjunct to the therapeutic armamentarium. It is particularly suited to the treatment of short high-flow vessels where coil migration and catheter dislodgment might occur. In the majority of cases no additional embolic agents are necessary but it may take up to 15 min for complete thrombosis to occur.
BACKGROUND AND PURPOSE: The Amplatzer Vascular Plug (AVP) is a self-expanding nitinol wire mesh vascular embolization device derived from the Amplatz septal occluder. We assessed the results of vascular embolization obtained using the AVP. METHODS: A retrospective review was carried out of 23 consecutive cases of vascular embolization using the AVP in a variety of different clinical settings. The AVP was chosen to have a diameter approximately 30-50% greater than the target vessel. The device was delivered via an appropriately sized guide catheter and was released when satisfactorily positioned. Additional embolic agents were used in some cases. RESULTS: All target vessels were successfully occluded with no device malpositioning or malfunction. In 14 (61%) patients the AVP was the sole embolic material. In the remaining patients additional agents were used, particularly in preoperative embolization of highly vascular renal tumors. The AVP does not cause instantaneous thrombosis and in high-flow situations thrombosis typically takes up to 15 min. CONCLUSION: The AVP is a safe, effective embolization device that provides a useful adjunct to the therapeutic armamentarium. It is particularly suited to the treatment of short high-flow vessels where coil migration and catheter dislodgment might occur. In the majority of cases no additional embolic agents are necessary but it may take up to 15 min for complete thrombosis to occur.
Authors: Lakshmi A Ratnam; Richard M Walkden; Graham J Munneke; Robert A Morgan; Anna-Maria Belli Journal: Eur Radiol Date: 2008-04-17 Impact factor: 5.315
Authors: Sun Ki Kim; Ho Jong Chun; Byung Gil Choi; Hae Giu Lee; Si Hyun Bae; Jong Young Choi Journal: Jpn J Radiol Date: 2011-02-27 Impact factor: 2.374
Authors: S Marlene Grenon; Joel Gagnon; York Hsiang; Ravi Sidhu; David Taylor; Jason Clement; Jerry Chen Journal: Can J Surg Date: 2009-12 Impact factor: 2.089