Measurement of electric fields induced in a human subject due to natural movements in static magnetic fields or exposure to alternating magnetic field gradients.

P M Glover1, R Bowtell.   

Abstract

A dual dipole electric field probe has been used to measure surface electric fields in vivo on a human subject over a frequency range of 0.1-800 Hz. The low-frequency electric fields were induced by natural body movements such as walking and turning in the fringe magnetic fields of a 3 T magnetic resonance whole-body scanner. The rate-of-change of magnetic field (dB/dt) was also recorded simultaneously by using three orthogonal search coils positioned near to the location of the electric field probe. Rates-of-change of magnetic field for natural body rotations were found to exceed 1 T s(-1) near the end of the magnet bore. Typical electric fields measured on the upper abdomen, head and across the tongue for 1 T s(-1) rate of change of magnetic field were 0.15+/-0.02, 0.077+/-0.003 and 0.015+/-0.002 V m(-1) respectively. Electric fields on the abdomen and chest were measured during an echo-planar sequence with the subject positioned within the scanner. With the scanner rate-of-change of gradient set to 10 T m(-1) s(-1) the measured rate-of-change of magnetic field was 2.2+/-0.1 T s(-1) and the peak electric field was 0.30+/-0.01 V m(-1) on the chest. The values of induced electric field can be related to dB/dt by a 'geometry factor' for a given subject and sensor position. Typical values of this factor for the abdomen or chest (for measured surface electric fields) lie in the range of 0.10-0.18 m. The measured values of electric field are consistent with currently available numerical modelling results for movement in static magnetic fields and exposure to switched magnetic field gradients.

Entities:  

Mesh:

Year:  2007        PMID: 18184992     DOI: 10.1088/0031-9155/53/2/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

2.  MR safety: simultaneous B0, dΦ/dt, and dB/dt measurements on MR-workers up to 7 T.

Authors:  Jens Groebner; Reiner Umathum; Michael Bock; Axel J Krafft; Wolfhard Semmler; Jaane Rauschenberg
Journal:  MAGMA       Date:  2011-07-14       Impact factor: 2.310

3.  Evaluation of occupational exposure in magnetic resonance sites.

Authors:  Giuseppe Acri; Barbara Testagrossa; Federica Causa; Maria Giulia Tripepi; Giuseppe Vermiglio; Raffaele Novario; Liviana Pozzi; Gloria Quadrelli
Journal:  Radiol Med       Date:  2013-12-12       Impact factor: 3.469

4.  3DQRS: a method to obtain reliable QRS complex detection within high field MRI using 12-lead electrocardiogram traces.

Authors:  T Stan Gregory; Ehud J Schmidt; Shelley Hualei Zhang; Zion Tsz Ho Tse
Journal:  Magn Reson Med       Date:  2014-01-22       Impact factor: 4.668

Review 5.  The revised electromagnetic fields directive and worker exposure in environments with high magnetic flux densities.

Authors:  Rianne Stam
Journal:  Ann Occup Hyg       Date:  2014-02-20

Review 6.  Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches.

Authors:  Valentina Hartwig; Stefania Romeo; Olga Zeni
Journal:  Med Biol Eng Comput       Date:  2018-01-18       Impact factor: 2.602

Review 7.  Gradient and shim technologies for ultra high field MRI.

Authors:  Simone A Winkler; Franz Schmitt; Hermann Landes; Joshua de Bever; Trevor Wade; Andrew Alejski; Brian K Rutt
Journal:  Neuroimage       Date:  2016-11-30       Impact factor: 6.556

8.  Repeated exposure attenuates the behavioral response of rats to static high magnetic fields.

Authors:  Thomas A Houpt; Jennifer A Cassell; Alison Hood; Megan DenBleyker; Ilana Janowitz; Kathleen Mueller; Breyda Ortega; James C Smith
Journal:  Physiol Behav       Date:  2010-01-05

9.  Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners.

Authors:  Katarzyna Sklinda; Jolanta Karpowicz; Andrzej Stępniewski
Journal:  Int J Environ Res Public Health       Date:  2021-12-22       Impact factor: 3.390

Review 10.  Occupational exposure to electromagnetic fields from medical sources.

Authors:  Rianne Stam; Sachiko Yamaguchi-Sekino
Journal:  Ind Health       Date:  2017-11-03       Impact factor: 2.179