Literature DB >> 3342658

Bias and precision of pulse oximeters and arterial oximeters.

B G Nickerson1, C Sarkisian, K Tremper.   

Abstract

We evaluated measurements of oxygen saturation from four noninvasive pulse oximeters, and two conventional arterial oximeters. Simultaneous measurements were obtained on each instrument on three different occasions in five healthy subjects breathing gas with an FIO2 of 1.00, 0.50, 0.21, 0.17, 0.15, 0.13 and 0.11. Mean bias relative to the sum of oxy-, carboxy-, and methemoglobins ranged from -0.4 to -2.6 percent for the pulse oximeters and +1.8 to -4.2 percent for the conventional oximeters. Two pulse oximeters performed well at all saturations down to 65 percent, while the others showed either increasing or decreasing bias below 80 percent saturation. Precision was approximately 2 percent for all instruments except one conventional oximeter with a precision of 0.7 percent. In the clinically relevant range, the performance of the noninvasive pulse oximeters was similar to conventional oximeters using arterial samples.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3342658     DOI: 10.1378/chest.93.3.515

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  21 in total

Review 1.  Hereditary haemorrhagic telangiectasia and pulmonary arteriovenous malformations: issues in clinical management and review of pathogenic mechanisms.

Authors:  C L Shovlin; M Letarte
Journal:  Thorax       Date:  1999-08       Impact factor: 9.139

Review 2.  Bronchopulmonary dysplasia: a new look at management.

Authors:  D P Southall; M P Samuels
Journal:  Arch Dis Child       Date:  1990-10       Impact factor: 3.791

Review 3.  Non-invasive monitoring in the pediatric ICU, Part III: Pulse oximeter.

Authors:  T Ravindranath
Journal:  Indian J Pediatr       Date:  1990 Mar-Apr       Impact factor: 1.967

Review 4.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 5.  Pulse oximetry and capnography in intensive and transitional care units.

Authors:  F Bongard; D Sue
Journal:  West J Med       Date:  1992-01

6.  Evaluation of a new reflectance pulse oximeter for clinical applications.

Authors:  Y Shimada; K Nakashima; Y Fujiwara; T Komatsu; M Kawanishi; J Takezawa; S Takatani
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

7.  Test of 20 similar intensive care ventilators in daily use conditions--evaluation of accuracy and performances.

Authors:  L Beydon; N Liu; J Hassapopoulos; F Rua; F Bonnet; A Harf; P Duvaldestin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

8.  Analysis of oxygen saturations recorded during dental intravenous sedations: a retrospective quality assurance of 3500 cases.

Authors:  Andre Viljoen; Karen Byth; Malcolm Coombs; Greg Mahoney; Douglas Stewart
Journal:  Anesth Prog       Date:  2011

Review 9.  Management of children with severe asthma exacerbation in the emergency department.

Authors:  Benjamin Volovitz; Moshe Nussinovitch
Journal:  Paediatr Drugs       Date:  2002       Impact factor: 3.022

10.  Oxygen and 99mTc-MAA shunt estimations in patients with pulmonary arteriovenous malformations: effects of changes in posture and lung volume.

Authors:  J Ueki; J M Hughes; A M Peters; G J Bellingan; M A Mohammed; J Dutton; W Ussov; D Knight; D Glass
Journal:  Thorax       Date:  1994-04       Impact factor: 9.139

View more