Literature DB >> 18091097

The influence of different speech processor and hearing aid settings on speech perception outcomes in electric acoustic stimulation patients.

Katrien Vermeire1, Ilona Anderson, Mark Flynn, Paul Van de Heyning.   

Abstract

OBJECTIVE: Electric acoustic stimulation (EAS) is an increasingly popular means of treating individuals with a steeply sloping mid-to-high frequency hearing loss, who traditionally do not benefit from hearing instruments. These persons often have too much residual hearing to be considered for a cochlear implant. Several studies have demonstrated the ability both to preserve the remaining low-frequency hearing in these individuals, and to provide significant benefit through combining a cochlear implant with a hearing aid to amplify the same ear. These improvements in performance have been especially noted in noise. Often overlooked is that these outcomes may be influenced by the fitting parameters of both the cochlear implant and the hearing aid.
DESIGN: This study assessed four EAS subjects, with a minimum of 1 month's EAS use, on eight different fitting parameters. Sentence testing in different noise levels (+15, +10, and +5 dB SPL) was conducted. Subjects also evaluated each condition using a visual analogue scale.
RESULTS: Results demonstrated that a reduced overlap of cochlear implant and hearing aid amplification produced best results across listening conditions.
CONCLUSIONS: The hearing aid should be fit to a patient-specific modified audiogram at least up to the point where low-frequency hearing is not measurable. The cochlear implant should be fit from a higher frequency point than is standard in patients without residual hearing in the implanted ear, to provide reduced overlap with the amplification provided by the hearing aid. Therefore, a small amount of overlap between the frequency ranges used by the hearing aid and the cochlear implant seems beneficial.

Entities:  

Mesh:

Year:  2008        PMID: 18091097     DOI: 10.1097/AUD.0b013e31815d6326

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  19 in total

1.  Effects of Removing Low-Frequency Electric Information on Speech Perception With Bimodal Hearing.

Authors:  Jennifer R Fowler; Jessica L Eggleston; Kelly M Reavis; Garnett P McMillan; Lina A J Reiss
Journal:  J Speech Lang Hear Res       Date:  2016-02       Impact factor: 2.297

2.  Evaluation of hearing aid frequency response fittings in pediatric and young adult bimodal recipients.

Authors:  Lisa S Davidson; Jill B Firszt; Chris Brenner; Jamie H Cadieux
Journal:  J Am Acad Audiol       Date:  2015-04       Impact factor: 1.664

Review 3.  [Hearing with combined electric acoustic stimulation].

Authors:  U Baumann; S Helbig
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

4.  Effects of lower frequency-to-electrode allocations on speech and pitch perception with the hybrid short-electrode cochlear implant.

Authors:  Lina A J Reiss; Ann E Perreau; Christopher W Turner
Journal:  Audiol Neurootol       Date:  2012-08-14       Impact factor: 1.854

Review 5.  A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices.

Authors:  Paola V Incerti; Teresa Y C Ching; Robert Cowan
Journal:  Trends Amplif       Date:  2013-03

6.  Speech masking release in Hybrid cochlear implant users: Roles of spectral and temporal cues in electric-acoustic hearing.

Authors:  Viral D Tejani; Carolyn J Brown
Journal:  J Acoust Soc Am       Date:  2020-05       Impact factor: 1.840

7.  Optimizing the combination of acoustic and electric hearing in the implanted ear.

Authors:  Sue A Karsten; Christopher W Turner; Carolyn J Brown; Eun Kyung Jeon; Paul J Abbas; Bruce J Gantz
Journal:  Ear Hear       Date:  2013 Mar-Apr       Impact factor: 3.570

8.  Preserved acoustic hearing in cochlear implantation improves speech perception.

Authors:  Sterling W Sheffield; Kelly Jahn; René H Gifford
Journal:  J Am Acad Audiol       Date:  2015-02       Impact factor: 1.664

9.  Two ears and two (or more?) devices: a pediatric case study of bilateral profound hearing loss.

Authors:  Rosalie M Uchanski; Lisa S Davidson; Sharon Quadrizius; Ruth Reeder; Jamie Cadieux; Jerrica Kettel; Richard A Chole
Journal:  Trends Amplif       Date:  2009-06

10.  The effects of bilateral electric and bimodal electric--acoustic stimulation on language development.

Authors:  Susan Nittrouer; Christopher Chapman
Journal:  Trends Amplif       Date:  2009-08-26
View more