A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances.

Laura J Barbagallo1, Gang Shen, Allan S Jones, Michael V Swain, Peter Petocz, M Ali Darendeliler.   

Abstract

The force imparted by removable thermoplastic appliances (RTA) onto teeth has not been investigated in the past. This investigation was designed to explore a novel methodology to measure the magnitude and identify the pattern of this force. Eight patients with moderate malocclusion were selected. In each patient, the palatally mal-positioned upper first premolar was corrected by wearing a series of four ClearSmile RTA over a duration of 8 weeks. When constructing RTA, the ClearSmile Company was advised that the amount of movement to be programmed into each appliance was 0.5 mm. The Pressurex film was used to measure the pressure generated by ClearSmile RTA against the palatal surface of the upper first premolar for buccal tipping movement. Three measurements were conducted respectively upon the issue and retrieval of each appliance (after 2 weeks of wear), resulting in 24 pressure measurements for each patient. Digital imaging and spectrophotometry analysis were employed to quantify the stain intensity mounted by the pressure on the films. The irrelevant forces were subtracted out to allow an assessment of the force purely acting to buccally repositioning the tooth. The results revealed that (1) the mean force magnitude over 2 weeks of RTA wear was 1.12 N (SE = 0.72 N); (2) the higher force magnitude of 5.12 N (SE = 0.80 N) seen at the issue of the appliance declined drastically to -2.67 N at the time of retrieval. These findings suggest that ClearSmile RTA exerts a high level of force against the tooth to be moved at the initial stage followed by a rapid force diminish.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18085439     DOI: 10.1007/s10439-007-9424-5

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  14 in total

1.  Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation.

Authors:  Fayez Elkholy; Thanapon Panchaphongsaphak; Fatih Kilic; Falko Schmidt; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-11       Impact factor: 1.938

2.  The influence of occlusal forces on force delivery properties of aligners during rotation of an upper central incisor.

Authors:  Wolfram Hahn; Benjamin Engelke; Klaus Jung; Henning Dathe; Franz-Joseph Kramer; Tina Rödig; Dietmar Kubein-Meesenburg; Rudolf M Gruber
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

3.  Computer-aided finite element model for biomechanical analysis of orthodontic aligners.

Authors:  Tarek M Elshazly; Christoph Bourauel; Mostafa Aldesoki; Ahmed Ghoneima; Moosa Abuzayda; Wael Talaat; Sameh Talaat; Ludger Keilig
Journal:  Clin Oral Investig       Date:  2022-08-22       Impact factor: 3.606

4.  Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor.

Authors:  Wolfram Hahn; Benjamin Engelke; Klaus Jung; Henning Dathe; Julia Fialka-Fricke; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

5.  Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances.

Authors:  Naohisa Kohda; Masahiro Iijima; Takeshi Muguruma; William A Brantley; Karamdeep S Ahluwalia; Itaru Mizoguchi
Journal:  Angle Orthod       Date:  2012-10-04       Impact factor: 2.079

6.  The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva.

Authors:  Biao Xiang; Xingxing Wang; Gang Wu; Yichen Xu; Menghan Wang; Yanjing Yang; Qingyu Wang
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

7.  Rapid tooling method for soft customized removable oral appliances.

Authors:  Mika Salmi; Jukka Tuomi; Rauno Sirkkanen; Tuula Ingman; Antti Mäkitie
Journal:  Open Dent J       Date:  2012-05-09

8.  Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor.

Authors:  Xiaowei Li; Chaochao Ren; Zheyao Wang; Pai Zhao; Hongmei Wang; Yuxing Bai
Journal:  Korean J Orthod       Date:  2016-03-18       Impact factor: 1.372

9.  Effects of Attachment of Plastic Aligner in Closing of Diastema of Maxillary Dentition by Finite Element Method.

Authors:  Yukiko Yokoi; Atsushi Arai; Jun Kawamura; Tomoko Uozumi; Yohei Usui; Norimasa Okafuji
Journal:  J Healthc Eng       Date:  2019-03-03       Impact factor: 2.682

10.  The essential work of fracture of thermoplastic orthodontic retainer materials.

Authors:  Albert L Pascual; Cynthia S Beeman; E Preston Hicks; Heather M Bush; Richard J Mitchell
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.