Literature DB >> 20050752

The essential work of fracture of thermoplastic orthodontic retainer materials.

Albert L Pascual1, Cynthia S Beeman, E Preston Hicks, Heather M Bush, Richard J Mitchell.   

Abstract

OBJECTIVE: To investigate whether oral cleansing agents affect the essential work of fracture (EWF) and plastic work of fracture (PWF) for two types of orthodontic thermoplastic retainer materials.
MATERIALS AND METHODS: Polyethylene-terephthalate-glycol (PETG; Tru-Tain Splint) and polypropylene/ethylene-propylene rubber (PP-EPR) blend (Essix-C+) sheets were compared. For each material, six sets of 25 sheets were thermoformed into double-edge-notched-tension specimens; subsets of five specimens were formed with internotch distances (L) equal to 6, 8, 10, 12, or 14 mm, respectively. Sets were stored (160 hours, 25 degrees C) in air (DRY), distilled water (DW), Original Listerine (LIS), mint Crest ProHealth (CPH), 3% hydrogen peroxide (HP), or Polident solution (POL). Specimens were fractured in tension at 2.54 mm/min. Areas under load-elongation curves were measured to determine total work of fracture (W(f)). Linear regressions (W(f) vs L [n = 25]) yielded intercepts (EWF) and slopes (PWF). Ninety-five percent confidence intervals were used to evaluate differences in EWF and PWF estimates.
RESULTS: PP-EPR blends showed higher EWFs after storage in HP vs storage in DW. PP-EPR blend showed higher EWFs after storage in CPH vs PETG. After HP storage, PP-EPR exhibited lower PWFs than with any other storage conditions. PP-EPR exhibited higher PWFs than PETG after storage in DRY, DW, and LIS.
CONCLUSIONS: Compared with DW, none of the cleansers decreased the energy to initiate fracture. With one exception, no cleanser decreased the energy to continue plastic fracture extension. In PP-EPR blend, increased resistance to fracture initiation was observed with CPH and HP, yet, surprisingly, HP decreased resistance to plastic fracture growth.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20050752      PMCID: PMC8985721          DOI: 10.2319/042809-232.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  4 in total

1.  Inference by eye: confidence intervals and how to read pictures of data.

Authors:  Geoff Cumming; Sue Finch
Journal:  Am Psychol       Date:  2005 Feb-Mar

2.  Inference by eye: reading the overlap of independent confidence intervals.

Authors:  Geoff Cumming
Journal:  Stat Med       Date:  2009-01-30       Impact factor: 2.373

3.  Wear comparison of thermoplastic materials used for orthodontic retainers.

Authors:  Gary D Gardner; William J Dunn; Louis Taloumis
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-09       Impact factor: 2.650

4.  A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances.

Authors:  Laura J Barbagallo; Gang Shen; Allan S Jones; Michael V Swain; Peter Petocz; M Ali Darendeliler
Journal:  Ann Biomed Eng       Date:  2007-12-18       Impact factor: 3.934

  4 in total
  4 in total

1.  Long-term effects of various cleaning methods on polypropylene/ethylene copolymer retainer material.

Authors:  Emily Wible; Manika Agarwal; Sibel Altun; Tyler Ramir; Grace Viana; Carla Evans; Henry Lukic; Spiro Megremis; Phimon Atsawasuwan
Journal:  Angle Orthod       Date:  2019-01-02       Impact factor: 2.079

2.  Mechanical Characterization of Thermoplastic Aligner Materials: Recommendations for Test Parameter Standardization.

Authors:  F Elkholy; S Schmidt; M Amirkhani; F Schmidt; B G Lapatki
Journal:  J Healthc Eng       Date:  2019-05-29       Impact factor: 2.682

3.  ATR-FTIR Analysis and One-Week Stress Relaxation of Four Orthodontic Aligner Materials.

Authors:  Florina Jaggy; Spiros Zinelis; Georgios Polychronis; Raphael Patcas; Marc Schätzle; George Eliades; Theodore Eliades
Journal:  Materials (Basel)       Date:  2020-04-16       Impact factor: 3.623

4.  Force Distribution of a Novel Core-Reinforced Multilayered Mandibular Advancement Device.

Authors:  Hyo-Won Ahn; Soo-Yeon Lee; Hobeen Yu; Jin-Young Park; Kyung-A Kim; Su-Jung Kim
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.