BACKGROUND: The objective of this study was to evaluate risk-adjusted sequential probability ratio test control charts for the detection of significant discrepancies between institution or individual interventional cardiologist postprocedural mortality rates and national or local event rate expectations.
METHODS: Eight thousand nine hundred forty-two percutaneous coronary interventional procedures were performed by 27 operators between January 1, 2002, and November 30, 2006. The institution-based evaluation included all procedures, and the individual-based evaluations included 8750 procedures performed by 18 operators who had each done at least 100 PCI procedures. Risk-adjusted sequential probability ratio test control charts were developed to assess whether the odds ratios (ORs) for death were >2.0 for alpha = beta = 0.10. The American College of Cardiology 1.1 prediction model was used to risk-adjust both the institution and individuals, and an additional local model was used for individuals.
RESULTS: After national risk adjustment, the local institution did not show mortality of more than a 1.5 OR. Two operators had a >2.0 mortality OR after national risk adjustment, and one of those remained elevated after local risk adjustment. Of 18 operators, 10 had insufficient data to allow us to accept or reject the hypothesis of increased risk.
CONCLUSIONS: The local institution performed within national expectations, but 1 operator was identified as having poor performance, which prompted an in-depth review of that operator's cases. The review revealed that the operator had an unusually high number of patients who presented with risk factors not included in the risk-adjustment models. This study highlights the utility of risk-adjusted sequential probability ratio test as a method for outcomes monitoring and quality control in interventional cardiology.

Entities:  

Mesh:

Year:  2007        PMID: 18082501     DOI: 10.1016/j.ahj.2007.08.022

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  11 in total

1.  iDASH: integrating data for analysis, anonymization, and sharing.

Authors:  Lucila Ohno-Machado; Vineet Bafna; Aziz A Boxwala; Brian E Chapman; Wendy W Chapman; Kamalika Chaudhuri; Michele E Day; Claudiu Farcas; Nathaniel D Heintzman; Xiaoqian Jiang; Hyeoneui Kim; Jihoon Kim; Michael E Matheny; Frederic S Resnic; Staal A Vinterbo
Journal:  J Am Med Inform Assoc       Date:  2011-11-10       Impact factor: 4.497

2.  Development of inpatient risk stratification models of acute kidney injury for use in electronic health records.

Authors:  Michael E Matheny; Randolph A Miller; T Alp Ikizler; Lemuel R Waitman; Joshua C Denny; Jonathan S Schildcrout; Robert S Dittus; Josh F Peterson
Journal:  Med Decis Making       Date:  2010-03-30       Impact factor: 2.583

3.  CRS and HIPEC for PMP-Use of the LC-CUSUM to Determine the Number of Procedures Required to Attain a Minimal Level of Proficiency in Delivering the Combined Modality Treatment.

Authors:  Aditi Bhatt; Antony George; Sanket Mehta
Journal:  Indian J Surg Oncol       Date:  2017-08-12

4.  National Veterans Health Administration inpatient risk stratification models for hospital-acquired acute kidney injury.

Authors:  Robert M Cronin; Jacob P VanHouten; Edward D Siew; Svetlana K Eden; Stephan D Fihn; Christopher D Nielson; Josh F Peterson; Clifton R Baker; T Alp Ikizler; Theodore Speroff; Michael E Matheny
Journal:  J Am Med Inform Assoc       Date:  2015-06-23       Impact factor: 4.497

5.  An evaluation of a distributed medical device safety surveillance system: the DELTA network study.

Authors:  Venkatesan D Vidi; Michael E Matheny; Sharon Donnelly; Frederic S Resnic
Journal:  Contemp Clin Trials       Date:  2011-02-26       Impact factor: 2.226

6.  Automated surveillance to detect postprocedure safety signals of approved cardiovascular devices.

Authors:  Frederic S Resnic; Thomas P Gross; Danica Marinac-Dabic; Nilsa Loyo-Berrios; Sharon Donnelly; Sharon-Lise T Normand; Michael E Matheny
Journal:  JAMA       Date:  2010-11-10       Impact factor: 56.272

7.  Risk-adjusted number-between failures charting procedures for monitoring a patient care process for acute myocardial infarctions.

Authors:  Fah Fatt Gan; Tess Tan
Journal:  Health Care Manag Sci       Date:  2010-09

8.  Maintaining a National Acute Kidney Injury Risk Prediction Model to Support Local Quality Benchmarking.

Authors:  Sharon E Davis; Jeremiah R Brown; Chad Dorn; Dax Westerman; Richard J Solomon; Michael E Matheny
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2022-08-12

9.  Validation of an automated safety surveillance system with prospective, randomized trial data.

Authors:  Michael E Matheny; David A Morrow; Lucila Ohno-Machado; Christopher P Cannon; Marc S Sabatine; Frederic S Resnic
Journal:  Med Decis Making       Date:  2008-11-17       Impact factor: 2.583

10.  Evaluation of an automated safety surveillance system using risk adjusted sequential probability ratio testing.

Authors:  Michael E Matheny; Sharon-Lise T Normand; Thomas P Gross; Danica Marinac-Dabic; Nilsa Loyo-Berrios; Venkatesan D Vidi; Sharon Donnelly; Frederic S Resnic
Journal:  BMC Med Inform Decis Mak       Date:  2011-12-14       Impact factor: 2.796