Literature DB >> 18071852

Biochemical evaluation of an artificial anal sphincter made from shape memory alloys.

Hongjian Liu1, Yun Luo, Masaru Higa, Xiumin Zhang, Yoshifumi Saijo, Yasuyuki Shiraishi, Kazumitsu Sekine, Tomoyuki Yambe.   

Abstract

Severe anal incontinence is a socially incapacitating disorder and a major unresolved clinical problem that has a considerable negative impact on quality of life. In this study, we developed a new artificial anal sphincter using shape memory alloys (SMAs) in order to improve the quality of life of such patients and evaluated the influence of this sphincter on blood serum chemistry in animal experiments. The artificial anal sphincter was driven by two Ti-Ni SMA actuators sandwiching the intestine and was implanted in three female goats. Blood was collected from the jugular vein on days 1 and 4; at weeks 1 and 2; and at months 1, 2, and 3, postoperatively. Biochemical parameters including total protein, albumin, total bilirubin, aspartate amino-transferase, blood urea nitrogen, creatinine, and C-reactive protein were examined. The time courses of total bilirubin and aspartate amino transferase of the three goats were within the baseline levels after 1 week of implantation and remained normal, demonstrating no liver function complications. The blood urea nitrogen and creatinine levels remained within the normal range, indicating no renal function complications. The total protein and albumin fluctuated within the normal range throughout the duration of this study. In these goats, it was also found that the level of C-reactive protein did not increase and that there was no stricture of the intestine where the artificial sphincter was attached. Our findings indicate that the artificial sphincter SMA demonstrated no adverse influence on blood serum chemistry and exhibited an effective system performance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18071852     DOI: 10.1007/s10047-007-0395-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  15 in total

1.  On the transformation behaviour, mechanical properties and biocompatibility of two niti-based shape memory alloys: NiTi42 and NiTi42Cu7.

Authors:  M Es-Souni; M Es-Souni; H F Brandies
Journal:  Biomaterials       Date:  2001-08       Impact factor: 12.479

2.  Development of an implantable artificial anal sphincter by the use of the shape memory alloy.

Authors:  S Amae; M Wada; Y Luo; H Nakamura; S Yoshida; T Kamiyama; T Yambe; T Takagi; S Nitta; R Ohi
Journal:  ASAIO J       Date:  2001 Jul-Aug       Impact factor: 2.872

3.  Development of an implantable artificial anal sphincter using a shape memory alloy.

Authors:  Kotaro Nishi; Takamichi Kamiyama; Motoshi Wada; Shintaro Amae; Tomohiro Ishii; Toshiyuki Takagi; Yun Luo; Takeshi Okuyama; Tomoyuki Yambe; Yutaka Hayashi; Ryoji Ohi
Journal:  J Pediatr Surg       Date:  2004-01       Impact factor: 2.545

4.  In vivo performance and biocompatibility of the MagScrew ventricular assist device.

Authors:  Soren Schenk; Stephan Weber; Viviane Luangphakdy; Christine R Flick; Ji-Feng Chen; Masahiro Inoue; Michael W Kopcak; Yoshio Ootaki; Kazuyoshi Doi; Raymond Dessoffy; Gordon B Hirschman; Nicholas G Vitale; Peter A Chapman; William A Smith; Kiyotaka Fukamachi
Journal:  ASAIO J       Date:  2003 Sep-Oct       Impact factor: 2.872

Review 5.  Ectopic placement of AMS 800 urinary control system pressure-regulating balloon.

Authors:  S K Wilson; J R Delk
Journal:  Urology       Date:  2005-01       Impact factor: 2.649

6.  Preclinical development of SMA artificial anal sphincters.

Authors:  Yun Luo; Masaru Higa; Shintaro Amae; Toshiyuki Takagi; Tomoyuki Yambe; Takeshi Okuyama; Hiromu Tanaka; Yasuyuki Kakubari; Hidetoshi Matsuki
Journal:  Minim Invasive Ther Allied Technol       Date:  2006       Impact factor: 2.442

7.  Biomechanical evaluation of an artificial anal sphincter prosthesis.

Authors:  C A Hajivassiliou; K B Carter; I G Finlay
Journal:  J Med Eng Technol       Date:  1997 May-Aug

8.  University of Wisconsin versus histidine-tryptophan-ketoglutarate for tissue preservation in live-donor liver transplantation.

Authors:  Ashok Jain; Ravi Mohanka; Mark Orloff; Peter Abt; Randeep Kashyap; Jackie Cullen; Kerrie Lansing; Adel Bozorgzadeh
Journal:  Exp Clin Transplant       Date:  2006-06       Impact factor: 0.945

9.  Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.

Authors:  B Thierry; M Tabrizian; C Trepanier; O Savadogo; L Yahia
Journal:  J Biomed Mater Res       Date:  2000-09-15

10.  Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter.

Authors:  C J Vaizey; M A Kamm; D M Gold; C I Bartram; S Halligan; R J Nicholls
Journal:  Lancet       Date:  1998-07-11       Impact factor: 79.321

View more
  4 in total

Review 1.  Challenges faced in the clinical application of artificial anal sphincters.

Authors:  Ming-hui Wang; Ying Zhou; Shuang Zhao; Yun Luo
Journal:  J Zhejiang Univ Sci B       Date:  2015-09       Impact factor: 3.066

Review 2.  Journal of Artificial Organs 2007: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

3.  Successful implantation of physiologically functional bioengineered mouse internal anal sphincter.

Authors:  Shreya Raghavan; Eiichi A Miyasaka; Mohamed Hashish; Sita Somara; Robert R Gilmont; Daniel H Teitelbaum; Khalil N Bitar
Journal:  Am J Physiol Gastrointest Liver Physiol       Date:  2010-06-17       Impact factor: 4.052

Review 4.  Artificial Muscle Devices: Innovations and Prospects for Fecal Incontinence Treatment.

Authors:  Elisa Fattorini; Tobia Brusa; Christian Gingert; Simone E Hieber; Vanessa Leung; Bekim Osmani; Marco D Dominietto; Philippe Büchler; Franc Hetzer; Bert Müller
Journal:  Ann Biomed Eng       Date:  2016-02-29       Impact factor: 3.934

  4 in total