Literature DB >> 10880117

Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.

B Thierry1, M Tabrizian, C Trepanier, O Savadogo, L Yahia.   

Abstract

Nickel-titanium (NiTi) alloy derives its biocompatibility and good corrosion resistance from a homogeneous oxide layer mainly composed of TiO(2), with a very low concentration of nickel. In this article, we described the corrosion behavior of NiTi alloys after mechanical polishing, electropolishing, and sterilization processes using cyclic polarization and atomic absorption. As a preparative surface treatment, electropolishing decreased the amount of nickel on the surface and remarkably improved the corrosion behavior of the alloy by increasing the mean breakdown potential value and the reproducibility of the results (0.99 +/- 0.05 V/SCE vs. 0.53 +/- 0. 42). Ethylene oxide and Sterrad(R) sterilization techniques did not modify the corrosion resistance of electropolished NiTi, whereas a steam autoclave and, to a lesser extent, peracetic acid sterilization produced scattered breakdown potential. In comparing the corrosion resistance of common biomaterials, NiTi ranked between 316L stainless steel and Ti6A14V even after sterilization. Electropolished NiTi and 316L stainless-steel alloys released similar amounts of nickel after a few days of immersion in Hank's solution. Measurements by atomic absorption have shown that the amount of released nickel from passive dissolution was below the expected toxic level in the human body. Auger electron spectroscopy analyses indicated surface contamination by Ca and P on NiTi during immersion, but no significant modification in oxide thickness was observed.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10880117     DOI: 10.1002/1097-4636(20000915)51:4<685::aid-jbm17>3.0.co;2-s

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  13 in total

1.  [Use of a nickel-titanium piston with a shape memory feature].

Authors:  D Beutner; K-B Hüttenbrink
Journal:  HNO       Date:  2007-11       Impact factor: 1.284

2.  Biochemical evaluation of an artificial anal sphincter made from shape memory alloys.

Authors:  Hongjian Liu; Yun Luo; Masaru Higa; Xiumin Zhang; Yoshifumi Saijo; Yasuyuki Shiraishi; Kazumitsu Sekine; Tomoyuki Yambe
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731

3.  Nitinol Carbofilm coated stents for peripheral applications: study in the porcine model.

Authors:  M Prunotto; C Isaia; M A Gatti; E Monari; E Pasquino; M Galloni
Journal:  J Mater Sci Mater Med       Date:  2005-12       Impact factor: 3.896

4.  A High-Throughput Structural and Electrochemical Study of Metallic Glass Formation in Ni-Ti-Al.

Authors:  Howie Joress; Brian L DeCost; Suchismita Sarker; Trevor M Braun; Sidra Jilani; Ryan Smith; Logan Ward; Kevin J Laws; Apurva Mehta; Jason R Hattrick-Simpers
Journal:  ACS Comb Sci       Date:  2020-06-24       Impact factor: 3.784

5.  Porous NiTi shape memory alloys produced by SHS: microstructure and biocompatibility in comparison with Ti2Ni and TiNi3.

Authors:  Paola Bassani; Silvia Panseri; Andrea Ruffini; Monica Montesi; Martina Ghetti; Claudio Zanotti; Anna Tampieri; Ausonio Tuissi
Journal:  J Mater Sci Mater Med       Date:  2014-06-14       Impact factor: 3.896

6.  [First experiences with a new nickel-titanium piston with a shape memory feature].

Authors:  J Hornung; J Zenk; B Schick; J Wurm; H Iro
Journal:  HNO       Date:  2007-02       Impact factor: 1.284

7.  A novel retractable laparoscopic device for mapping gastrointestinal slow wave propagation patterns.

Authors:  Rachel Berry; Niranchan Paskaranandavadivel; Peng Du; Mark L Trew; Gregory O'Grady; John A Windsor; Leo K Cheng
Journal:  Surg Endosc       Date:  2016-04-29       Impact factor: 4.584

8.  Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses.

Authors:  Karolin J Paprottka; Philipp M Paprottka; Maximilian F Reiser; Tobias Waggershauser
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

9.  Current practices in corrosion, surface characterization, and nickel leach testing of cardiovascular metallic implants.

Authors:  Srinidhi Nagaraja; Matthew Di Prima; David Saylor; Erica Takai
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-02-16       Impact factor: 3.368

10.  Retrospective analysis of the results of implanting Nitinol pistons with heat-crimping piston loops in stapes surgery.

Authors:  Joachim Albert Hornung; Christoph Brase; Alessandro Bozzato; Johannes Zenk; Bernhard Schick; Heinrich Iro
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-01       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.