Literature DB >> 18059914

Signal detection in power-law noise: effect of spectrum exponents.

Arthur E Burgess1, Philip F Judy.   

Abstract

Many natural backgrounds have approximately isotropic power spectra of the power-law form, P(f)=K/f(beta), where f is radial frequency. For natural scenes and mammograms, the values of the exponent, beta, range from 1.5 to 3.5. The ideal observer model predicts that for signals with certain properties and backgrounds that can be treated as random noise, a plot of log (contrast threshold) versus log (signal size) will be linear with slope, m, given by: m=(beta-2)/2. This plot is referred to as a contrast-detail (CD) diagram. It is interesting that this predicts a detection threshold that is independent of signal size for beta equal to 2. We present two-alternative forced-choice (2AFC) detection results for human and channelized model observers of a simple signal in filtered noise with exponents from 1.5 to 3.5. The CD diagram results are in good agreement with the prediction of this equation.

Entities:  

Mesh:

Year:  2007        PMID: 18059914     DOI: 10.1364/josaa.24.000b52

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  25 in total

1.  On the orientation of mammographic structure.

Authors:  I Reiser; S Lee; R M Nishikawa
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

5.  Radiomics robustness assessment and classification evaluation: A two-stage method demonstrated on multivendor FFDM.

Authors:  Kayla Robinson; Hui Li; Li Lan; David Schacht; Maryellen Giger
Journal:  Med Phys       Date:  2019-03-12       Impact factor: 4.071

6.  Comparison of power spectra for tomosynthesis projections and reconstructed images.

Authors:  Emma Engstrom; Ingrid Reiser; Robert Nishikawa
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

7.  A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms.

Authors:  Subok Park; Robert Jennings; Haimo Liu; Aldo Badano; Kyle Myers
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

Review 8.  A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

9.  Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities.

Authors:  Lin Chen; Craig K Abbey; John M Boone
Journal:  Phys Med Biol       Date:  2013-02-19       Impact factor: 3.609

10.  Investigating simulation-based metrics for characterizing linear iterative reconstruction in digital breast tomosynthesis.

Authors:  Sean D Rose; Adrian A Sanchez; Emil Y Sidky; Xiaochuan Pan
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

View more