OBJECTIVES: The aim of the present study was to compare the diagnostic accuracy of F-speed conventional film, unenhanced digital images and inversion-enhanced digital images for the detection of osseous defects in patients with vertical bone defects.
METHODS: 23 vertical osseous defects in the mandible were evaluated. Intrasurgical measurements were made from the cementoenamel junction (CEJ) to the deepest extension of the osseous defects by one of the researchers. Radiographic measurements were obtained on conventional F-speed film, unenhanced digital images and inversion-enhanced digital images by six examiners. From each measure the corresponding probe measure was subtracted to form a difference score.
RESULTS: Significant differences in means of difference scores were found among examiners within each imaging modality, and among the modalities within five of the six examiners. A significant (P<0.001) interaction term for the ANOVA indicated that differences among modality means were not the same across all examiners. The difference means were significantly different from zero for five of the six examiners with conventional F-speed film, four of six with inversion enhanced digital images, but for only one of six for unenhanced digital images. The reliability coefficient computed on a per examiner basis was 0.90 for conventional F-speed film, 0.94 for unenhanced digital image and 0.79 for inversion-enhanced digital image.
CONCLUSIONS: In this study, unenhanced digital imaging was found to be superior to conventional F-speed film and inversion-enhanced digital images for accurately imaging periodontal osseous defects in patients.

Entities:  

Mesh:

Year:  2007        PMID: 18033948     DOI: 10.1259/dmfr/29704550

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  8 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

3.  Influence of individual brightness and contrast adjustment on accuracy of radiographic measurements of infrabony defects.

Authors:  D Tihanyi; I Gera; P Eickholz
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

4.  Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

Authors:  S R Ashwinirani; Girish Suragimath; H P Jaishankar; Prasad Kulkarni; Shobha C Bijjaragi; Varsha Ajit Sangle
Journal:  J Clin Diagn Res       Date:  2015-02-01

5.  A Subjective Assessment of Perceived Clarity of Indirect Digital Images and Processed Digital Images with Conventional Intra-oral Periapical Radiographs.

Authors:  Suchetha N Malleshi; Mahima V G; Anudeepa Raina; Karthikeya Patil
Journal:  J Clin Diagn Res       Date:  2013-08-01

6.  The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries.

Authors:  Shimasadat Miri; Sandra Mehralizadeh; Donya Sadri; Mahmood Reza Kalantar Motamedi; Parisa Soltani
Journal:  Imaging Sci Dent       Date:  2015-09-09

7.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01

8.  Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects.

Authors:  Seyed Jalal Pourhashemi; Zahra Ghoncheh; Mohammad Taghi Kiani; Raheleh Emami; Mohamad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.