Literature DB >> 18030446

[In vivo biomechanics of unicondylar knee replacement performed using minimally invasive technique].

J-N A Argenson1, R D Komistek, S Akizuki.   

Abstract

Disturbed kinematics of the knee plays an important role in early failure of a unicondylar knee prosthesis (UNI). Recent studies on kinematics have shown that an intact anterior cruciate ligament (ACL) is important for a successful UNI. In this study, in vivo fluoroscopic analysis of knee kinematics was performed for 30 patients with a successful medial UNI implanted with the use of minimally invasive technique. The three-dimensional data of the CAD model were used for evaluating the sagittal translation as well as the axial rotation during deep knee bending and one gait cycle. The anteroposterior translation for flexion was, on average, -5.3 mm (-15.7-3.3; standard deviation 5.3). In most cases, the contact point was more posterior compared with the normal knee. During gait, the average anteroposterior translation was 0.8 mm, which is comparable to that of the normal knee. Axial rotation for deep knee bending was, on average, 8 degrees (-1.3-22.0; standard deviation 5.7), whereas 28 of the 30 knees showed normal axial rotation. During gait, an average axial rotation of 0.94 degrees was observed. The kinematic pattern of each of the subjects did not replicate the average pattern in most of the patients. An insufficient ACL may be suspected as the cause of the pathological kinematic pattern observed in some of these patients.

Entities:  

Mesh:

Year:  2007        PMID: 18030446     DOI: 10.1007/s00132-007-1170-8

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  17 in total

1.  An in vivo determination of patellofemoral contact positions.

Authors:  R D Komistek; D A Dennis; J A Mabe; S A Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  2000-01       Impact factor: 2.063

2.  Rapid recovery after oxford unicompartmental arthroplasty through a short incision.

Authors:  A J Price; J Webb; H Topf; C A Dodd; J W Goodfellow; D W Murray
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

3.  In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty.

Authors:  Jean-Noël A Argenson; Richard D Komistek; Jean-Manuel Aubaniac; Douglas A Dennis; Eric J Northcut; Dylan T Anderson; Serge Agostini
Journal:  J Arthroplasty       Date:  2002-12       Impact factor: 4.757

4.  The mini incision: routine approach.

Authors:  Jean-Noël A Argenson
Journal:  Orthopedics       Date:  2004-05       Impact factor: 1.390

5.  Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee.

Authors:  J N Argenson; J J O'Connor
Journal:  J Bone Joint Surg Br       Date:  1992-03

6.  Early catastrophic tibial component wear after unicompartmental knee arthroplasty.

Authors:  S H Palmer; P J Morrison; A C Ross
Journal:  Clin Orthop Relat Res       Date:  1998-05       Impact factor: 4.176

7.  Early failure of the porous coated anatomic cemented unicompartmental knee arthroplasty. Aids to diagnosis and revision.

Authors:  J L Knight; R D Atwater; J Guo
Journal:  J Arthroplasty       Date:  1997-01       Impact factor: 4.757

8.  Unicompartmental knee arthroplasty. Clinical experience at 6- to 10-year followup.

Authors:  R A Berger; D D Nedeff; R M Barden; M M Sheinkop; J J Jacobs; A G Rosenberg; J O Galante
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

9.  Unicompartmental arthroplasty of the knee. Cadaver study of the importance of the anterior cruciate ligament.

Authors:  J T Møller; R E Weeth; J O Keller; S Nielsen
Journal:  Acta Orthop Scand       Date:  1985-04

Review 10.  The unicompartmental knee: design and technical considerations in minimizing wear.

Authors:  Jean-Noël A Argenson; Sebastien Parratte
Journal:  Clin Orthop Relat Res       Date:  2006-11       Impact factor: 4.176

View more
  2 in total

1.  Improved kinematics of total knee replacement following partially navigated modified gap-balancing technique.

Authors:  Clemens Baier; Wolfgang Fitz; Ben Craiovan; Armin Keshmiri; Sebastian Winkler; Robert Springorum; Joachim Grifka; Johannes Beckmann
Journal:  Int Orthop       Date:  2013-10-15       Impact factor: 3.075

2.  Postural Stability after Unicondylar Knee Arthroplasty and Patient-Specific Interpositional Knee Spacer.

Authors:  J Goetz; M Baeurle; S Dullien; J Grifka; F Koeck; C Baier
Journal:  Biomed Res Int       Date:  2017-07-13       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.