Literature DB >> 17999101

Quantitative T2 measurement of a single voxel with arbitrary shape using pinwheel excitation and CPMG acquisition.

Qin Qin1, John C Gore, Robin A de Graaf, Mark D Does.   

Abstract

OBJECTIVE: The aim of this study is to present a new approach for making quantitative single-voxel T (2) measurements from an arbitrarily shaped region of interest (ROI), where the advantage of the signal-to-noise ratio (SNR) per unit time of the single-voxel approach over conventional imaging approach can be achieved.
MATERIALS AND METHODS: Two-dimensional (2D) spatially selective radiofrequency (RF) pulses are proposed in this work for T (2) measurements based on using interleaved spiral trajectories in excitation k-space (pinwheel excitation pulses), combined with a summed Carr-Purcell Meiboom-Gill (CPMG) echo acquisition. The technique is described and compared to standard multi-echo imaging methods, on a two-compartment water phantom and an excised brain tissue.
RESULTS: The studies show good agreement between imaging and our method. The measured improvement factors of SNR per unit time of our single-voxel approach over imaging approach are close to the predicted values.
CONCLUSION: Measuring T (2) relaxation times from a selected ROI of arbitrary shape using a single-voxel rather than an imaging approach can increase the SNR per unit time, which is critical for dynamic T (2) or multi-component T (2) measurements.

Entities:  

Mesh:

Year:  2007        PMID: 17999101      PMCID: PMC2634838          DOI: 10.1007/s10334-007-0088-9

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Multicomponent T2 relaxation of in vivo skeletal muscle.

Authors:  G Saab; R T Thompson; G D Marsh
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

2.  Effects of exercise on muscle transverse relaxation determined by MR imaging and in vivo relaxometry.

Authors:  G Saab; R T Thompson; G D Marsh
Journal:  J Appl Physiol (1985)       Date:  2000-01

3.  Rapid acquisition transverse relaxometric imaging.

Authors:  M D Does; J C Gore
Journal:  J Magn Reson       Date:  2000-11       Impact factor: 2.229

4.  Practical T2 quantitation for clinical applications.

Authors:  C S Poon; R M Henkelman
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

5.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

6.  31P spectroscopic localization using pinwheel NMR excitation pulses.

Authors:  C J Hardy; P A Bottomley
Journal:  Magn Reson Med       Date:  1991-02       Impact factor: 4.668

7.  Measurement of in vivo multi-component T2 relaxation times for brain tissue using multi-slice T2 prep at 1.5 and 3 T.

Authors:  Joonmi Oh; Eric T Han; Daniel Pelletier; Sarah J Nelson
Journal:  Magn Reson Imaging       Date:  2005-12-19       Impact factor: 2.546

8.  MR measurement of relative water content and multicomponent T2 relaxation in human breast.

Authors:  S J Graham; M J Bronskill
Journal:  Magn Reson Med       Date:  1996-05       Impact factor: 4.668

9.  Criteria for analysis of multicomponent tissue T2 relaxation data.

Authors:  S J Graham; P L Stanchev; M J Bronskill
Journal:  Magn Reson Med       Date:  1996-03       Impact factor: 4.668

Review 10.  Spatial localization in NMR spectroscopy in vivo.

Authors:  P A Bottomley
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

View more
  3 in total

1.  Correcting partial volume effects in biexponential T2 estimation of small lesions.

Authors:  Chuan Huang; Jean-Philippe Galons; Christian G Graff; Eric W Clarkson; Ali Bilgin; Bobby Kalb; Diego R Martin; Maria I Altbach
Journal:  Magn Reson Med       Date:  2014-04-17       Impact factor: 4.668

2.  Dependencies of multi-component T2 and T1ρ relaxation on the anisotropy of collagen fibrils in bovine nasal cartilage.

Authors:  Nian Wang; Yang Xia
Journal:  J Magn Reson       Date:  2011-07-07       Impact factor: 2.229

3.  Multi-components of T2 relaxation in ex vivo cartilage and tendon.

Authors:  Shaokuan Zheng; Yang Xia
Journal:  J Magn Reson       Date:  2009-02-21       Impact factor: 2.229

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.