Literature DB >> 17949670

Effect of higher-order aberrations on visual function in keratoconic eyes with a rigid gas permeable contact lens.

Kazuno Negishi1, Takashi Kumanomido, Yoshikazu Utsumi, Kazuo Tsubota.   

Abstract

PURPOSE: To study the effect of higher-order aberrations (HOAs) on visual function in keratoconus with a rigid gas permeable (RGP) contact lens (CLs).
DESIGN: Retrospective nonrandomized study.
METHODS: Thirteen eyes of 10 subjects with keratoconus who wore a RGP CLs (KC-RGP group), 15 eyes of nine normal subjects (normal group), and 14 eyes of nine subjects who wore a RGP CLs (RGP group) who had no ocular diseases except for refractive errors and had 20/20 or better-corrected visual acuity were included in this study. The root-mean-square (RMS) of the third-, fourth-, fifth-, and sixth-order Zernike coefficients (total HOAs), the RMS of the third-order Zernike coefficients (S3) (coma-like aberration), the RMS of the fourth-order coefficients (S4) (spherical-like aberrations), and the area under the log contrast sensitivity function (AULCSF) were evaluated.
RESULTS: The AULCSF in the KC-RGP group was significantly lower than in the other two groups. The total HOAs, S3, and S4 in the KC-RGP group were significantly higher than in the other two groups. There were significant negative correlations between the area under the log contrast sensitivity function and the total HOAs, S3, and S4.
CONCLUSIONS: The visual performance in a keratoconic eye with a RGP CLs degrades compared with normal eyes with and without RGP CLs, even if the corrected VA is good. The degradation is assumed to be related to residual HOAs in a keratoconic eye with a RGP CLs.

Entities:  

Mesh:

Year:  2007        PMID: 17949670     DOI: 10.1016/j.ajo.2007.08.004

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  27 in total

1.  Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty.

Authors:  Yue Shi; Hope M Queener; Jason D Marsack; Ayeswarya Ravikumar; Harold E Bedell; Raymond A Applegate
Journal:  J Vis       Date:  2013-06-11       Impact factor: 2.240

Review 2.  [Keratoconus lenses: the small correction miracle].

Authors:  U Klühspies; A Grunder; S Goebels; F Schirra; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

3.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

4.  Bevel toric multicurve rigid gas-permeable lens for keratoconus.

Authors:  Ryoji Yanai; Kiichi Ueda; Koh-Hei Sonoda
Journal:  Jpn J Ophthalmol       Date:  2012-12-07       Impact factor: 2.447

5.  Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.

Authors:  Qing Yu; Jiang-Xiu Wu; He-Ning Zhang; Sheng Ye; Shi-Qi Dong; Chen-Hao Zhang
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

6.  Comparison of Wavefront-guided and Best Conventional Scleral Lenses after Habituation in Eyes with Corneal Ectasia.

Authors:  Gareth D Hastings; Raymond A Applegate; Lan Chi Nguyen; Matthew J Kauffman; Roxana T Hemmati; Jason D Marsack
Journal:  Optom Vis Sci       Date:  2019-04       Impact factor: 1.973

7.  LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Parthasarathi Kalaiselvan; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Optom Vis Sci       Date:  2018-04       Impact factor: 1.973

8.  Template-based correction of high-order aberration in keratoconus.

Authors:  Jason D Marsack; Jos J Rozema; Carina Koppen; Marie-Jose Tassignon; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2013-04       Impact factor: 1.973

9.  Performance of wavefront-guided soft lenses in three keratoconus subjects.

Authors:  Jason D Marsack; Katrina E Parker; Raymond A Applegate
Journal:  Optom Vis Sci       Date:  2008-12       Impact factor: 1.973

10.  Wavefront-guided scleral lens prosthetic device for keratoconus.

Authors:  Ramkumar Sabesan; Lynette Johns; Olga Tomashevskaya; Deborah S Jacobs; Perry Rosenthal; Geunyoung Yoon
Journal:  Optom Vis Sci       Date:  2013-04       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.