Literature DB >> 17926956

Model-based crosstalk compensation for simultaneous 99mTc/123I dual-isotope brain SPECT imaging.

Yong Du1, Benjamin M W Tsui, Eric C Frey.   

Abstract

In this work, we developed a model-based method to estimate and compensate for the crosstalk contamination in simultaneous 123I and 99mTc dual isotope brain single photo emission computed tomography imaging. The model-based crosstalk compensation (MBCC) includes detailed modeling of photon interactions inside both the object and the detector system. In the method, scatter in the object is modeled using the effective source scatter estimation technique, including contributions from all the photon emissions. The effects of the collimator-detector response, including the penetration and scatter components due to high-energy 123I photons, are modeled using precalculated tables of Monte Carlo simulated point-source response functions obtained from sources in air at various distances from the face of the collimator. The model-based crosstalk estimation method was combined with iterative reconstruction based compensation to reduce contamination due to crosstalk. The MBCC method was evaluated using Monte Carlo simulated and physical phantom experimentally acquired simultaneous dual-isotope data. Results showed that, for both experimental and simulation studies, the model-based method provided crosstalk estimates that were in good agreement with the true crosstalk. Compensation using MBCC improved image contrast and removed the artifacts for both Monte Carlo simulated and experimentally acquired data. The results were in good agreement with images acquired without any crosstalk contamination.

Mesh:

Substances:

Year:  2007        PMID: 17926956     DOI: 10.1118/1.2768863

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Distribution of cell-free and cell-associated HIV surrogates in the colon after simulated receptive anal intercourse in men who have sex with men.

Authors:  Nicolette A Louissaint; Sridhar Nimmagadda; Edward J Fuchs; Rahul P Bakshi; Ying-Jun Cao; Linda A Lee; Jeff Goldsmith; Brian S Caffo; Yong Du; Karen E King; Frederick A Menendez; Michael S Torbenson; Craig W Hendrix
Journal:  J Acquir Immune Defic Syndr       Date:  2012-01-01       Impact factor: 3.731

2.  Quantification of the spatial distribution of rectally applied surrogates for microbicide and semen in colon with SPECT and magnetic resonance imaging.

Authors:  Ying J Cao; Brian S Caffo; Edward J Fuchs; Linda A Lee; Yong Du; Liye Li; Rahul P Bakshi; Katarzyna Macura; Wasif A Khan; Richard L Wahl; Lisa A Grohskopf; Craig W Hendrix
Journal:  Br J Clin Pharmacol       Date:  2012-12       Impact factor: 4.335

3.  Distribution of cell-free and cell-associated HIV surrogates in the female genital tract after simulated vaginal intercourse.

Authors:  Nicolette A Louissaint; Edward J Fuchs; Rahul P Bakshi; Sridhar Nimmagadda; Yong Du; Katarzyna J Macura; Karen E King; Richard Wahl; Arthur J Goldsmith; Brian Caffo; Ying Jun Cao; Jean Anderson; Craig W Hendrix
Journal:  J Infect Dis       Date:  2012-01-25       Impact factor: 5.226

4.  Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Authors:  Yong Du; Eric C Frey
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.

Authors:  Na Song; Yong Du; Bin He; Eric C Frey
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

6.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

7.  Simultaneous 99mTc-MDP/123I-MIBG tumor imaging using SPECT-CT: phantom and constructed patient studies.

Authors:  Yothin Rakvongthai; Georges El Fakhri; Ruth Lim; Ali A Bonab; Jinsong Ouyang
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

8.  Development of a 4D Digital Phantom for Tracer Kinetic Modeling and Analysis of Dynamic Perfusion PET and SPECT Simulation Studies.

Authors:  George S K Fung; Takahiro Higuchi; Min Jae Park; W Paul Segars; Benjamin M W Tsui
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011-10

9.  Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

Authors:  Wataru Takeuchi; Atsuro Suzuki; Tohru Shiga; Naoki Kubo; Yuichi Morimoto; Yuichiro Ueno; Keiji Kobashi; Kikuo Umegaki; Nagara Tamaki
Journal:  EJNMMI Phys       Date:  2016-06-29

10.  Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction.

Authors:  Yoshihiro Yamada; Shintaro Nakano; Youdou Gatate; Nanami Okano; Toshihiro Muramatsu; Shigeyuki Nishimura; Ichiei Kuji; Kenji Fukushima; Ichiro Matsunari
Journal:  J Nucl Cardiol       Date:  2019-01-02       Impact factor: 5.952

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.