Literature DB >> 17900939

Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements.

M Loubele1, N Van Assche, K Carpentier, F Maes, R Jacobs, D van Steenberghe, P Suetens.   

Abstract

OBJECTIVES: To compare the accuracy of cone-beam computerized tomography (CBCT) and multislice CT (MSCT) for linear jaw bone measurements. STUDY
DESIGN: An ex vivo formalin-fixed human maxilla was imaged with both CBCT (Accuitomo 3D; Morita, Kyoto, Japan) and MSCT (4-slice Somatom VolumeZoom and 16-slice Somatom Sensation 16; Siemens, Erlangen, Germany). The MSCT images were reconstructed using different reconstruction filters to optimize bone visualization (U70u and U90u for VolumeZoom, H30s and H60s for Sensation 16). Before scanning, triplets of small gutta-percha markers were glued onto the soft tissues overlying the maxillary bone on the top and on both sides of the alveolar ridge to define a set of reproducible linear measurements in 11 planes. Image measurements were performed by 2 observers. The gold standard was determined by means of physical measurements with a caliper by 3 observers.
RESULTS: The accuracy of the linear measurements was 0.35 +/- 1.31 mm (U70u) and 0.06 +/- 1.23 mm (U90u) for the Somatom VolumeZoom, 0.24 +/- 1.20 mm (H60s) and 0.54 +/- 1.14 mm (H30s) for the Sensation 16, and -0.09 +/- 1.64 mm for the Accuitomo 3D. Statistical analysis with 2-way analysis of variance showed no significant inter- or intraobserver disagreement for the physical or the radiologic measurements. There was also no significant difference for the measurements on the different reconstruction filters.
CONCLUSION: Both CBCT and MSCT yield submillimeter accuracy for linear measurements on an ex vivo specimen.

Entities:  

Mesh:

Year:  2007        PMID: 17900939     DOI: 10.1016/j.tripleo.2007.05.004

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  48 in total

1.  Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site.

Authors:  A Dawood; J Brown; V Sauret-Jackson; S Purkayastha
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

2.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 4.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

5.  Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging.

Authors:  F G Draenert; F Gebhart; M Berthold; M Gosau; W Wagner
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

6.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

7.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

8.  Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom.

Authors:  J Bamba; K Araki; A Endo; T Okano
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

9.  Generation of three-dimensional prototype models based on cone beam computed tomography.

Authors:  J Th Lambrecht; D C Berndt; R Schumacher; M Zehnder
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-15       Impact factor: 2.924

10.  The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography.

Authors:  Xiao Li; Zhu-Kun Jin; Hui Zhao; Kai Yang; Jian-Min Duan; Wei-Jian Wang
Journal:  Surg Radiol Anat       Date:  2013-03-23       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.