Literature DB >> 23525640

The prevalence, length and position of the anterior loop of the inferior alveolar nerve in Chinese, assessed by spiral computed tomography.

Xiao Li1, Zhu-Kun Jin, Hui Zhao, Kai Yang, Jian-Min Duan, Wei-Jian Wang.   

Abstract

PURPOSE: This study used spiral computed tomography to identify the anterior loop of the inferior alveolar nerve, and to measure its length and position in Chinese. This information may be useful to safely install endosseous implants in the most distal area of the interforaminal region.
METHODS: Sixty-eight Chinese patients were included in this retrospective study. Patients were scanned by 64-slice spiral computed tomography, and the prevalence, length, and position of the anterior loop were assessed using the multiplanar capabilities of software.
RESULTS: An anterior loop could be identified in 83.1% of the cases, with a mean length of 2.09 mm (range 0-5.31 mm). The mean distance from the superior border of the mental foramen to the alveolar crest was 13.00 mm, and the mean distance from the superior border of the origin of the anterior loop to the alveolar crest was 17.83 mm.
CONCLUSIONS: The anterior loop was highly prevalent in Chinese, and the length of the anterior loop was highly variable. Therefore, we recommend that drilling commences from a location approximately 5.5 mm mesially from the mental foramen, when installing implants in the most distal interforaminal area.

Entities:  

Mesh:

Year:  2013        PMID: 23525640     DOI: 10.1007/s00276-013-1104-6

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  30 in total

1.  The location of the mental foramen in a selected Malay population.

Authors:  Wei Cheong Ngeow; Yusof Yuzawati
Journal:  J Oral Sci       Date:  2003-09       Impact factor: 1.556

2.  Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan.

Authors:  R Jacobs; N Mraiwa; D vanSteenberghe; F Gijbels; M Quirynen
Journal:  Dentomaxillofac Radiol       Date:  2002-09       Impact factor: 2.419

3.  Morphometrical and morphological study of mental foramen in dry dentulous mandibles of South Andhra population of India.

Authors:  Devi K Sankar; Sharmila P Bhanu; P J Susan
Journal:  Indian J Dent Res       Date:  2011 Jul-Aug

4.  Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant?

Authors:  Brion Benninger; Dan Miller; Anand Maharathi; Winthrop Carter
Journal:  J Oral Maxillofac Surg       Date:  2010-11-04       Impact factor: 1.895

5.  Vulnerability of the inferior alveolar nerve and mental nerve during genioplasty: an anatomic study.

Authors:  Kun Hwang; Whan Joon Lee; You Bong Song; In Hyuk Chung
Journal:  J Craniofac Surg       Date:  2005-01       Impact factor: 1.046

Review 6.  The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review.

Authors:  Gary Greenstein; Dennis Tarnow
Journal:  J Periodontol       Date:  2006-12       Impact factor: 6.993

7.  Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography.

Authors:  Yuki Uchida; Nobuhiro Noguchi; Masaaki Goto; Yoshio Yamashita; Tsunehiko Hanihara; Hitoshi Takamori; Iwao Sato; Taisuke Kawai; Takashi Yosue
Journal:  J Oral Maxillofac Surg       Date:  2009-04       Impact factor: 1.895

8.  Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures.

Authors:  Munetaka Naitoh; Kino Nakahara; Yutaka Suenaga; Kenichi Gotoh; Shintaro Kondo; Eiichiro Ariji
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-01

9.  Morphometrical analysis of the human mandibular canal: a CT investigation.

Authors:  Marcello Rodrigues de Oliveira Júnior; André Luis Santos Saud; Debora Rodrigues Fonseca; Bernardo De-Ary-Pires; Mário Ary Pires-Neto; Ricardo de Ary-Pires
Journal:  Surg Radiol Anat       Date:  2010-07-31       Impact factor: 1.246

10.  The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging.

Authors:  Dimitrios Apostolakis; Jackie E Brown
Journal:  Clin Oral Implants Res       Date:  2011-08-03       Impact factor: 5.977

View more
  15 in total

1.  Anatomical configuration of the inferior alveolar neurovascular bundle: a histomorphometric analysis.

Authors:  Sun-Kyoung Yu; Myoung-Hwa Lee; Yong Hyun Jeon; Yoon Young Chung; Heung-Joong Kim
Journal:  Surg Radiol Anat       Date:  2015-08-14       Impact factor: 1.246

2.  Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography.

Authors:  Eduarda Helena Leandro do Nascimento; Maria Luiza Dos Anjos Pontual; Andréa Dos Anjos Pontual; Danyel Elias da Cruz Perez; José Natal Figueiroa; Marco Antônio Gomes Frazão; Flávia Maria de Moraes Ramos-Perez
Journal:  Imaging Sci Dent       Date:  2016-06-23

3.  Anterior loop of the mental nerve, mental foramen and incisive nerve emergency: tridimensional assessment and surgical applications.

Authors:  Juan Carlos Prados-Frutos; Carmen Salinas-Goodier; Ángel Manchón; Rosa Rojo
Journal:  Surg Radiol Anat       Date:  2016-05-11       Impact factor: 1.246

4.  Anatomical landmarks of mandibular interforaminal region related to dental implant placement with 3D CBCT: comparison between edentulous and dental mandibles.

Authors:  Elif Sener; Erinc Onem; Gulcan Coskun Akar; Figen Govsa; Mehmet Asim Ozer; Yelda Pinar; Ali Mert; B Guniz Baksi Sen
Journal:  Surg Radiol Anat       Date:  2017-11-09       Impact factor: 1.246

5.  Morphological assessment of the anterior loop of the mandibular canal in Koreans.

Authors:  Sun-Kyoung Yu; Seog Kim; Shin Gu Kang; Jae Hyuk Kim; Kyeong Ok Lim; Seong-Ik Hwang; Heung-Joong Kim
Journal:  Anat Cell Biol       Date:  2015-03-20

6.  Assessment of Implant-Related Anatomical Landmarks in the Mandibular Interforaminal Region in an Iranian Population Using Cone-Beam Computed Tomography.

Authors:  Nafiseh Nikkerdar; Amin Golshah; Razieh Mahmoodivesali; Sepideh Falah-Kooshki
Journal:  Contemp Clin Dent       Date:  2022-06-21

7.  A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography.

Authors:  Aleksandar Vujanovic-Eskenazi; Jesus-Manuel Valero-James; María-Angeles Sánchez-Garcés; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-03-01

8.  3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean.

Authors:  Yong Hyun Jeon; Chul Kwon Lee; Hee-Jung Kim; Jae-Heon Chung; Heung-Joong Kim; Sun-Kyoung Yu
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

9.  Assessment of the anterior loop of mental nerve in an Iranian population using cone beam computed tomography scan.

Authors:  Mitra Karbasi Kheir; Mahnaz Sheikhi
Journal:  Dent Res J (Isfahan)       Date:  2017 Nov-Dec

10.  Morphometric Analysis of the Mental Foramen Using Cone-Beam Computed Tomography.

Authors:  Rudyard Dos Santos Oliveira; Maria Rodrigues Coutinho; Francine Kühl Panzarella
Journal:  Int J Dent       Date:  2018-03-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.