Literature DB >> 17899918

The squeaking hip: a cause for concern-disagrees.

Charlie C Yang1, Raymond H Kim, Douglas A Dennis.   

Abstract

Total hip arthroplasty with ceramic-on-ceramic bearing surfaces has demonstrated low wear with excellent clinical outcomes. More recently, concerns have surfaced because of the presence of audible squeaking in some ceramic-on-ceramic THA patients. The incidence of this phenomenon has been low and has infrequently required reoperation. The exact etiology of squeaking remains unclear but is likely related to variations in surgical technique, patient selection, and implant design, particularly those designs that result in premature femoral neck-acetabular component rim impingement such as the presence of modular ceramic liner designs that are placed within a titanium encasement which has an extended rim. Hopefully, with continued improvements in design, materials, and component positioning, squeaking following ceramic-on-ceramic THA can be minimized.

Entities:  

Mesh:

Year:  2007        PMID: 17899918     DOI: 10.3928/01477447-20070901-33

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  17 in total

1.  The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces.

Authors:  Christophe Chevillotte; Robert T Trousdale; Qingshan Chen; Olivier Guyen; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

2.  Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis.

Authors:  Adolph V Lombardi; Keith R Berend; Brian E Seng; Ian C Clarke; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

3.  Squeaking and microcracks in a delta-delta ceramic coupling: pin-on-disc study.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tadami Matsumoto; Kazuhiro Shintani
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-12

4.  The natural history of ceramic-on-ceramic prosthetic hip squeak and its impact on patients.

Authors:  David Owen; Nicholas Russell; Andrew Chia; Malcolm Thomas
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-12-09

5.  Factors affecting modular acetabular ceramic liner insertion: a biomechanical analysis.

Authors:  James P McAuley; Douglas A Dennis; Justin Grostefon; William G Hamilton
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 6.  Bearing surfaces in hip replacement - Evolution and likely future.

Authors:  Narinder Kumar; Gen N C Arora; Barun Datta
Journal:  Med J Armed Forces India       Date:  2014-08-04

7.  Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients.

Authors:  Tae-Hun Lee; Young-Wan Moon; Seung-Jae Lim; Youn-Soo Park
Journal:  Hip Pelvis       Date:  2014-06-30

8.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

Review 9.  Ceramic on Ceramic or Ceramic-on-polyethylene for Total Hip Arthroplasty: A Systemic Review and Meta-analysis of Prospective Randomized Studies.

Authors:  Yu-Lei Dong; Tao Li; Ke Xiao; Yan-Yan Bian; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2015-05-05       Impact factor: 2.628

Review 10.  Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Authors:  Guo-Liang Wu; Wei Zhu; Yan Zhao; Qi Ma; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

View more