BACKGROUND AND PURPOSE: Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess intra-aneurysmal pressure gradients in a canine aneurysmal model when compared with invasive measurements. MATERIALS AND METHODS: A total of 13 surgically created aneurysms in 8 canines were included in this study. Pressure measurements were performed in the parent vessel, aneurysm neck, and 5 regions within the aneurysmal sac with a microcatheter. PC-VIPR sequence was used to obtain cardiac-gated velocity measurements in a region covering the entire aneurysm. The velocity and pressure gradient maps derived from the PC-VIPR data were then coregistered with the anatomic DSA images and compared with catheter measurements. RESULTS: In 7 of the bifurcation aneurysms, the velocity flow maps demonstrated a recirculation flow pattern with a small neck-to-dome pressure gradient (mean, +0.5 mm Hg). In 1 bifurcation aneurysm, a flow jet extending from the neck to the dome with significantly greater pressure gradient (+50.2 mm Hg) was observed. All sidewall aneurysms had low flow in the sac with intermediate pressure gradients (mean, +8.3 mm Hg). High statistical correlation existed between PC-VIPR aneurysmal pressures and microcatheter pressure measurements (R = 0.82, P < .01). CONCLUSION: PC-VIPR can provide anatomic as well as noninvasive quantitative and qualitative hemodynamic information in the canine aneurysm model. The PC-VIPR intra-aneurysmal pressure measurements correlated well with catheter measurements.
BACKGROUND AND PURPOSE: Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess intra-aneurysmal pressure gradients in a canineaneurysmal model when compared with invasive measurements. MATERIALS AND METHODS: A total of 13 surgically created aneurysms in 8 canines were included in this study. Pressure measurements were performed in the parent vessel, aneurysm neck, and 5 regions within the aneurysmal sac with a microcatheter. PC-VIPR sequence was used to obtain cardiac-gated velocity measurements in a region covering the entire aneurysm. The velocity and pressure gradient maps derived from the PC-VIPR data were then coregistered with the anatomic DSA images and compared with catheter measurements. RESULTS: In 7 of the bifurcation aneurysms, the velocity flow maps demonstrated a recirculation flow pattern with a small neck-to-dome pressure gradient (mean, +0.5 mm Hg). In 1 bifurcation aneurysm, a flow jet extending from the neck to the dome with significantly greater pressure gradient (+50.2 mm Hg) was observed. All sidewall aneurysms had low flow in the sac with intermediate pressure gradients (mean, +8.3 mm Hg). High statistical correlation existed between PC-VIPR aneurysmal pressures and microcatheter pressure measurements (R = 0.82, P < .01). CONCLUSION: PC-VIPR can provide anatomic as well as noninvasive quantitative and qualitative hemodynamic information in the canineaneurysm model. The PC-VIPR intra-aneurysmal pressure measurements correlated well with catheter measurements.
Authors: Juan R Cebral; Marcelo A Castro; Sunil Appanaboyina; Christopher M Putman; Daniel Millan; Alejandro F Frangi Journal: IEEE Trans Med Imaging Date: 2005-04 Impact factor: 10.048
Authors: M Calderon-Arnulphi; S Amin-Hanjani; A Alaraj; M Zhao; X Du; S Ruland; X J Zhou; K R Thulborn; F T Charbel Journal: AJNR Am J Neuroradiol Date: 2011-08-11 Impact factor: 3.825
Authors: Thorsten A Bley; Kevin M Johnson; Christopher J François; Scott B Reeder; Mark L Schiebler; Benjamin R Landgraf; Daniel Consigny; Thomas M Grist; Oliver Wieben Journal: Radiology Date: 2011-08-03 Impact factor: 11.105
Authors: J Mikhail Kellawan; John W Harrell; Alejandro Roldan-Alzate; Oliver Wieben; William G Schrage Journal: J Cereb Blood Flow Metab Date: 2016-01-01 Impact factor: 6.200
Authors: Yiping Li; Raheel Ahmed; Leonardo A Rivera-Rivera; James A Stadler; Patrick Turski; Beverly Aagaard-Kienitz Journal: World Neurosurg Date: 2019-03-05 Impact factor: 2.104