Influence of apical constriction diameter on Root ZX apex locator precision.

Manuela Herrera1, Camilo Abalos, Amparo Jimenez Planas, Rafael Llamas.   

Abstract

Small-diameter hand files are systematically used to determine the initial working length and to establish patency of the root canal. In wide canals, electronic apex locator accuracy might be influenced by file size. This article reports on a study to assess the influence of apical constriction diameter on the precision of the Root ZX apex locator by using files of varying diameter on teeth with 3 different degrees of apical widening: 0.37, 0.62, and 1.02 mm. Ten extracted single-root teeth, stored in saline solution at 37 degrees C, were sectioned at the enamel-cement junction and embedded in an alginate mold. Initial working length (L0) was determined with a #10 Kerr file, and canals were irrigated with either 50% citric acid or 5.25% sodium hypochlorite. To assess the ability of the locator to identify the narrowest area of the root canal as constriction diameter increased, the canal was progressively widened by insertion of files of increasing diameter (10-100) at a point L0+1 mm. After each enlargement, the working length (L) was redetermined, with files from #10 (L10) up to the file used for widening. Comparison of statistical results was based on the difference between final working length and initial length (L10) for each apical width. Statistical analysis was carried out with analysis of variance test for comparison of means. Results showed that at apical constriction widths of 0.37 and 0.62 mm, there was no significant difference between initial working lengths as determined by a Kerr #10 file and final working lengths after widening with files of up to #60. In those teeth whose apical width had been increased to 1.02 mm, there was no statistically significant difference between initial and final working lengths as measured by files from #10-#25; however, significant differences were apparent between #10 and #30, #35, or #40 (P<.05), and the degree of significance increased considerably (P<.001) for files #45 or greater. These results suggest that Root ZX apex locator precision varies as a function of apical constriction diameter.

Entities:  

Mesh:

Year:  2007        PMID: 17878091     DOI: 10.1016/j.joen.2007.05.009

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Evaluation of Correlation Between apical Diameter and File Size Using Propex Pixi Apex Locator.

Authors:  Sreeha Kaluva Kolanu; Nagesh Bolla; Sujana Varri; Jayaprakash Thummu; Sayesh Vemuri; Pragna Mandava
Journal:  J Clin Diagn Res       Date:  2014-12-05

2.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

3.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

4.  The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth.

Authors:  Maciej Janeczek; Piotr Kosior; Dagmara Piesiak-Pańczyszyn; Krzysztof Dudek; Aleksander Chrószcz; Agnieszka Czajczyńska-Waszkiewicz; Małgorzata Kowalczyk-Zając; Aleksandra Gabren-Syller; Karol Kirstein; Aleksandra Skalec; Ewelina Bryła; Maciej Dobrzyński
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

5.  Evaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals.

Authors:  Hamid Jafarzadeh; Masoud Beyrami; Maryam Forghani
Journal:  Iran Endod J       Date:  2017

6.  A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An ex vivo study.

Authors:  Divya Saxena; Suparna Ganguly Saha; Anuj Bharadwaj; Neelam Vijaywargiya; Sandeep Dubey; Shubham Kala
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

7.  Influence of calcium hydroxide residues after using different irrigants on the accuracy of two electronic apex locators: An in vitro study.

Authors:  Nooshin Sadat Shojaee; Zahra Zaeri; Mohammad Mehdi Shokouhi; Fereshteh Sobhnamayan; Alireza Adl
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

8.  In vitro detection of simulated apical root perforation with two electronic apex locators.

Authors:  Kiumars Nazari Moghaddam; Shahrzad Nazari; Leila Shakeri; Kiamars Honardar; Farshid Mirmotalebi
Journal:  Iran Endod J       Date:  2010-02-20

9.  An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.

Authors:  Kalyan Vinayak Chakravarthy Pishipati
Journal:  Iran Endod J       Date:  2013-08-01

10.  Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An In Vitro Study.

Authors:  Masoud Saatchi; Shiva Iravani; Mehrdad Akhavan Khaleghi; Amin Mortaheb
Journal:  Iran Endod J       Date:  2017
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.