Imaging the neonate in the incubator: an investigation of the technical, radiological and nursing issues.

S J Mutch1, S D P Wentworth.   

Abstract

Modern neonatal incubators incorporate an X-ray tray device into the mattress support structure to facilitate patient examination with minimal disturbance and distress. However, the usual method of examination is to place the image plate directly underneath the baby. Users often cite radiological reasons for not using X-ray trays but modern quantitative evidence is lacking. This work looks at the technical and clinical aspects of imaging neonates in incubators and the impact that these may have in determining the imaging protocol. A number of hospitals were surveyed to determine their current method of examination and the reasons for their preference. Experimental measurements of the radiological impact of using (or not using) the X-ray tray were performed for a range of neonatal incubators. The average dose to the image plate was 5.9 microGy (range 5.4-6.4 microGy) for the "plate on mattress" method and 3.0 microGy (2.0-3.8 microGy) when using the tray--a 49% reduction owing to the mattress support materials. However, when using a computed radiography (CR) imaging system, the image quality differences were marginal. Survey results indicated that nurses preferred to use the tray but that radiographers were reluctant. We conclude that incubator manufacturers could do much to improve the radiological performance of their equipment and we offer recommendations. We also conclude that, with appropriate nurse and radiographer training and the advent of CR imaging systems, use of X-ray tray facilities may optimize imaging of the neonate in the incubator.

Entities:  

Mesh:

Year:  2007        PMID: 17875591     DOI: 10.1259/bjr/88577258

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

1.  A feasibility study on reduction of the entrance-surface dose to neonates by use of a new digital mobile X-ray system.

Authors:  Satoru Utsunomiya; Hajime Monzen; Mami Akimoto; Nobutaka Mukumoto; Yoshitomo Ishihara; Takehiko Shiinoki; Mitsuhiro Nakamura; Yuki Miyabe; Sayaka Sato; Satoru Matsuo; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2012-10-20

2.  Neonatal digital chest radiography- should we be using additional copper filtration?

Authors:  Jenna Ruth Tugwell-Allsup; Rhys Wyn Morris; Kate Thomas; Richard Hibbs; Andrew England
Journal:  Br J Radiol       Date:  2021-12-14       Impact factor: 3.039

3.  Effect of comfort pads and incubator design on neonatal radiography.

Authors:  Xia Jiang; Michael Baad; Ingrid Reiser; Kate A Feinstein; Zhengfeng Lu
Journal:  Pediatr Radiol       Date:  2015-09-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.