Literature DB >> 17873983

Diagnostic quality of panoramic views obtained by a newly developed digital volume tomography device for maxillofacial imaging.

Robert A Mischkowski1, Larry Ritter, Jörg Neugebauer, Timo Dreiseidler, Erwin Keeve, Joachim E Zöller.   

Abstract

OBJECTIVE: To compare the diagnostic quality of 2-dimensional panoramic views generated from imaging data acquired by a newly developed cone beam machine with the diagnostic quality of conventional digital orthopantomograms (OPTs). METHOD AND MATERIALS: Thirty panoramic views reconstructed from digital volume tomograms (DVT) obtained by the pre-retail version of Galileos (Sirona Dental Systems), a newly developed compact cone beam device, were compared with 30 OPT images acquired by Orthophos XG Plus (Sirona Dental Systems). Diagnostic quality was assessed by 3 observers on criteria regarding detection of diagnosis-related findings, image quality, and visualization of anatomic structures in the maxillomandibular area. Wilcoxon rank sum test was applied for paired comparison.
RESULTS: Statistical analysis showed no significant difference in diagnostic quality between both imaging modes using a calculation model based on 10 weighted criteria (P = .629). There was especially no statistically significant difference in the assessment of diagnosis-related findings detection (P = .163). Image quality of DVT panoramic views was significantly lower than that of OPT. Except for mandibular canal and alveolar ridge gingiva, all evaluated anatomic structures were visualized better by DVT. Intraclass correlation coefficients were consistently higher in the DVT group for all criteria but 2, although the difference was not statistically significant (P = .374).
CONCLUSIONS: DVT panoramic views perform better in diagnosis of specific lesions, whereas OPTs provide a better image quality for a general overview of the maxillomandibular area. The diagnostic quality of both imaging modes is, however, equal.

Entities:  

Mesh:

Year:  2007        PMID: 17873983

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  6 in total

1.  An in vitro comparison of subjective image quality of panoramic views acquired via 2D or 3D imaging.

Authors:  P Pittayapat; D Galiti; Y Huang; K Dreesen; M Schreurs; P Couto Souza; I R F Rubira-Bullen; F H Westphalen; R Pauwels; G Kalema; G Willems; R Jacobs
Journal:  Clin Oral Investig       Date:  2012-03-01       Impact factor: 3.573

2.  Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

Authors:  C Tomasi; E Bressan; B Corazza; S Mazzoleni; E Stellini; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2011-05       Impact factor: 2.419

3.  Investigation of an optimized scanning protocol for the dentomaxillofacial region using 320-slice multidetector computed tomography.

Authors:  Wei-Chan Lin; Hsueh-Han Wang; Wen-Lin Hsu; Bi-Hui Cao; De-Ji Chen; Chia-Jung Tsai
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

4.  Evaluation of trabecular pattern of mandible using fractal dimension, bone area fraction, and gray scale value: comparison of cone-beam computed tomography and panoramic radiography.

Authors:  Guldane Magat; Sevgi Ozcan Sener
Journal:  Oral Radiol       Date:  2018-01-17       Impact factor: 1.852

5.  Obstacles in spatial evaluation of CBCT-reformatted panoramic imaging.

Authors:  Johannes Wikner; Reinhard E Friedrich; Ashkan Rashad; Dirk Schulze; Henning Hanken; Max Heiland; Alexander Gröbe; Björn Riecke
Journal:  Dentomaxillofac Radiol       Date:  2016-03-09       Impact factor: 2.419

6.  Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis.

Authors:  Guldane Magat; Elif Oncu; Sevgi Ozcan; Kaan Orhan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2022-02-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.