Literature DB >> 20210451

Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography.

Ehsan Azimi1, Bin Liu, Mark E Brezinski.   

Abstract

For high-speed swept-source optical coherence tomography (SS-OCT), the real-time calibration process to convert the OCT signal to wave number space is highly essential. A novel calibration process/algorithm using a genetic algorithm and precise interpolation is developed. This algorithm is embedded and validated in a SS-OCT system with 16-kHz A-scan rate. The performance of the new algorithm is evaluated by measuring point spread functions at two distinct locations in the entire imaging range. The data is compared to the same system but embedded with a regular calibration algorithm, which demonstrates about 20% improvement in the axial resolution. The steady improvement at different locations of the range suggests the strong robustness of the algorithm, which will ultimately optimize the operation performance of this SS-OCT system in terms of resolution and dynamic range and improves details in biological tissues.

Entities:  

Mesh:

Year:  2010        PMID: 20210451      PMCID: PMC2830822          DOI: 10.1117/1.3285660

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  22 in total

1.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2005-12-01       Impact factor: 3.776

2.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

Authors:  Robert Huber; Desmond C Adler; James G Fujimoto
Journal:  Opt Lett       Date:  2006-10-15       Impact factor: 3.776

3.  High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm.

Authors:  V J Srinivasan; R Huber; I Gorczynska; J G Fujimoto; J Y Jiang; P Reisen; A E Cable
Journal:  Opt Lett       Date:  2007-02-15       Impact factor: 3.776

4.  Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles.

Authors:  R Huber; M Wojtkowski; K Taira; J Fujimoto; K Hsu
Journal:  Opt Express       Date:  2005-05-02       Impact factor: 3.894

5.  Characterization of Fourier domain mode-locked wavelength swept laser for optical coherence tomography imaging.

Authors:  Min Yong Jeon; Jun Zhang; Zhongping Chen
Journal:  Opt Express       Date:  2008-03-17       Impact factor: 3.894

6.  High-speed and wide bandwidth Fourier domain mode-locked wavelength swept laser with multiple SOAs.

Authors:  Min Yong Jeon; Jun Zhang; Qiang Wang; Zhongping Chen
Journal:  Opt Express       Date:  2008-02-18       Impact factor: 3.894

7.  Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determination.

Authors:  Mircea Mujat; B Hyle Park; Barry Cense; Teresa C Chen; Johannes F de Boer
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

8.  Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography.

Authors:  Bin Liu; Mark E Brezinski
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

9.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology.

Authors:  M E Brezinski; G J Tearney; B E Bouma; J A Izatt; M R Hee; E A Swanson; J F Southern; J G Fujimoto
Journal:  Circulation       Date:  1996-03-15       Impact factor: 29.690

10.  High speed full range complex spectral domain optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Rainer Leitgeb; Christoph Hitzenberger
Journal:  Opt Express       Date:  2005-01-24       Impact factor: 3.894

View more
  4 in total

1.  Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery.

Authors:  Xuan Liu; Marcin Balicki; Russell H Taylor; Jin U Kang
Journal:  Opt Express       Date:  2010-11-08       Impact factor: 3.894

2.  True logarithmic amplification of frequency clock in SS-OCT for calibration.

Authors:  Bin Liu; Ehsan Azimi; Mark E Brezinski
Journal:  Biomed Opt Express       Date:  2011-05-27       Impact factor: 3.732

3.  Practical Challenges of Current Video Rate OCT Elastography: Accounting for Dynamic and Static Tissue Properties.

Authors:  Mark E Brezinski
Journal:  J Lasers Opt Photonics       Date:  2014-12-12

4.  A Novel Mach-Zehnder Interferometer Using Eccentric-Core Fiber Design for Optical Coherence Tomography.

Authors:  Qiao Xiong; Xinglin Tong; Chengwei Deng; Cui Zhang; Pengfei Wang; Zhiyuan Zheng; Fang Liu
Journal:  Sensors (Basel)       Date:  2018-05-13       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.